Measurement of optic disc size: equivalence of methods to correct for ocular magnification
Open Access
- 1 June 1998
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 82 (6) , 643-649
- https://doi.org/10.1136/bjo.82.6.643
Abstract
AIMS To compare methods available to correct the magnification of images that result from the optics of the eye and identify errors, and source of error, of the methods. METHODS 11 methods were applied to ocular biometry data from three independent cohorts. Each method was compared with the method of Bennett, which uses most biometric data. The difference between each method and Bennett’s is the “error” of the method. The relation between the error and axial length, ametropia, and keratometry was explored by linear regression analysis. RESULTS Methods using axial length had the lowest mean (+0.5 to +2.6%) and standard deviation (0.6 to 1.2%) of errors. Of methods using keratometry and ametropia only, the lowest mean (−1.4% to +4.4%) and standard deviation (2.9 to 4.3%) of errors was found for a new method described in this paper, and that used by the Heidelberg retina tomograph (HRT). The highest mean error (+2.2 to +7.1%) was found for Littmann’s method. Littmann’s correction was larger than the HRT’s by 3.5 to 3.7%. The mean difference between the new and HRT methods and the “abbreviated axial length” method of Bennett is −1.3 to +2.0%. The error of the “keratometry and ametropia” methods is related to axial length. CONCLUSIONS Methods using axial length are most accurate. The abbreviated axial length method of Bennett differs little from more detailed calculations and is appreciably more accurate than methods using keratometry and ametropia alone. If axial length is unknown, the new and the HRT methods give results closest to the abbreviated axial length method.Keywords
This publication has 37 references indexed in Scilit:
- An appraisal of the accuracy of Littmann's method of determining the real dimension of a retinal objectActa Ophthalmologica Scandinavica, 1995
- Computerised intraocular lens calculation: clinical results and predictability.British Journal of Ophthalmology, 1989
- Image size in the fundus: structural evidence for wide-field retinal magnification factor.British Journal of Ophthalmology, 1988
- Zur Bestimmung der wahren Größe eines Objektes auf dem Hintergrund eines lebenden AugesKlinische Monatsblätter für Augenheilkunde, 1988
- A method of determining the equivalent powers of the eye and its crystalline lens without resort to phakometryOphthalmic and Physiological Optics, 1988
- On the calculation of power from curvature of the cornea.British Journal of Ophthalmology, 1986
- Zur Bestimmung der wahren Größe eines Objektes auf dem Hintergrund des lebenden AugesKlinische Monatsblätter für Augenheilkunde, 1982
- SOME ESSENTIAL OPTICAL FEATURES OF THE ZEISS FUNDUS CAMERAActa Ophthalmologica, 1977
- THE VARIATION AND COVARIATION OF CUP AND DISC DIAMETERSActa Ophthalmologica, 1976
- MEASUREMENT OF INTRAOCULAR DISTANCES BY ULTRASOUND AND COMPARISON BETWEEN OPTICAL AND ULTRASONIC DETERMINATIONS OF THE DEPTH OF THE ANTERIOR CHAMBERActa Ophthalmologica, 1963