Multivariate evaluation of factors influencing the performance of a formic acid biosensor for use in air monitoring
- 15 October 2001
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (11) , 2008-2014
- https://doi.org/10.1039/b104504k
Abstract
A formic acid biosensor for air monitoring has been evaluated using chemometric methods. Using experimental design eleven factors that could influence the performance of the biosensor were examined. The response matrices consisted of six parameters (steady state currents at three different formic acid concentrations and response rates during changes in formic acid concentrations) describing the performance of the biosensor. The data were evaluated using a combination of principal component analysis (PCA) and multiple linear regression (MLR). To confirm the conclusions from the PCA-MLR partial least squares (PLS) was also used. The most important factor for the biosensor performance was found to be the enzyme concentration. Using the information from the chemometric analyses the optimum operation conditions for the biosensor were determined. The steady state currents were increased by 18–30% and the initial two response rates increased by 47–89% compared with a biosensor that had not been optimised.Keywords
This publication has 14 references indexed in Scilit:
- Electronic tongues for environmental monitoring based on sensor arrays and pattern recognition: a reviewAnalytica Chimica Acta, 2000
- Amperometric biosensor for formic acid in airSensors and Actuators B: Chemical, 2000
- An insect-based BioFET as a bioelectronic noseSensors and Actuators B: Chemical, 2000
- Selection of variables for interpreting multivariate gas sensor dataAnalytica Chimica Acta, 1999
- Biosensors in air monitoringPublished by Royal Society of Chemistry (RSC) ,1999
- Multivariate evaluation of inhibition studies on an enzyme electrodes system with pesticides and mixtures of mercury and pesticidesAnalytica Chimica Acta, 1996
- Chemometric methods for the development of a biosensor system and the evaluation of inhibition studies with solutions and mixtures of pesticides and heavy metals Part 1. Development of an enzyme electrodes system for pesticide and heavy metal screening using selected chemometric methodsAnalytica Chimica Acta, 1996
- Multivariate response surface modelling by principal components analysisJournal of Chemometrics, 1989
- Cross-Validatory Estimation of the Number of Components in Factor and Principal Components ModelsTechnometrics, 1978
- THE DESIGN OF OPTIMUM MULTIFACTORIAL EXPERIMENTSBiometrika, 1946