A superconducting tunnel junction x-ray detector with performance limited by statistical effects
- 31 August 1998
- journal article
- Published by AIP Publishing in Applied Physics Letters
- Vol. 73 (9) , 1295-1297
- https://doi.org/10.1063/1.122372
Abstract
We have characterized a thin-film Nb/Al/AlOx/Al/Nb superconducting tunnel junction (STJ) optimized for low electronic noise as an x-ray detector in the 0.2–1 keV photon energy range. The spectra measured with this junction have high spectral purity with, to the best of our knowledge, the best energy resolution ever achieved with this type of detector in this energy band. The discrepancy between the theoretical and experimental energy resolution is only about 15%. Part of this small discrepancy may be explained by the fact that our junction has electrodes made from niobium/aluminum bilayers, while the theoretical result is for electrodes made from only one material. To the best of our knowledge, this is the first time that resolution achieved with a STJ x-ray detector is in agreement with the resolution predicted from statistical fluctuations in the creation and tunneling of quasiparticles.Keywords
This publication has 10 references indexed in Scilit:
- Energy resolution and high count rate performance of superconducting tunnel junction x-ray spectrometersReview of Scientific Instruments, 1998
- Response of niobium-based superconducting tunnel junctions in the soft-x-ray region 0.15–6.5 keVPhysical Review B, 1996
- Soft x-ray (50-1800 eV) measurements of niobium superconducting tunnel junctionsPublished by SPIE-Intl Soc Optical Eng ,1995
- Statistical noise due to tunneling in superconducting tunnel junction detectorsApplied Physics Letters, 1994
- Energy-resolving superconducting x-ray detectors with charge amplification due to multiple quasiparticle tunnelingApplied Physics Letters, 1993
- The properties of niobium superconducting tunneling junctions as X-ray detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992
- YBCO thin films on sapphire with an epitaxial MgO bufferIEEE Transactions on Magnetics, 1991
- A simple and robust niobium Josephson junction integrated circuit processIEEE Transactions on Magnetics, 1991
- Quasiparticle trapping and the quasiparticle multiplierApplied Physics Letters, 1987
- Possibility of high resolution detectors using superconducting tunnel junctionsNuclear Instruments and Methods in Physics Research, 1982