Intratester and Intertester Reliability of the KT-1000 Arthrometer in the Assessment of Posterior Laxity of the Knee
- 1 July 1997
- journal article
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 25 (4) , 479-485
- https://doi.org/10.1177/036354659702500410
Abstract
We measured tibial translation in the knees of 22 sub jects with posterior cruciate ligament tears or recon structions by using the KT-1000 arthrometer. To as sess the reliability of the device, two testers made measurements. One tester was a novice and the sec ond tester had substantial clinical experience with the KT-1000 arthrometer. The quadriceps neutral angle was found for the uninvolved knee. Anterior and pos terior translation and total anterior-posterior excursion were then measured. The quadriceps neutral angle was then reproduced in the involved knee and the same measurements were taken. Each subject was tested twice by each tester. The intraclass correlation coefficient values for the novice, experienced, and in tertester reliability were 0.67, 0.79, and 0.62, respec tively, for corrected posterior translation; 0.59, 0.68, and 0.64, respectively, for corrected anterior transla tion; 0.70, 0.74, and 0.29, respectively, for quadriceps neutral angle; and 0.84, 0.83, and 0.62, respectively, for total anterior-posterior excursion. Ninety-five per cent confidence intervals for the novice, experienced, and intertester reliability were ±2.95, ±2.53, and ±3.27 mm, respectively, for corrected posterior trans lation; ±3.99, ±3.89, and ±3.74 mm, respectively, for corrected anterior translation; and ± 10.70°, ± 11.73°, and ± 16.25°, respectively, for quadriceps neutral an gle. The KT-1000 arthrometer was found to be a mod erately reliable tool for the measurement of tibial trans lation in patients with posterior cruciate ligament tears and reconstructions.Keywords
This publication has 24 references indexed in Scilit:
- Measurement reproducibility of two commercial knee test devicesJournal of Orthopaedic Research, 1991
- Comparison of clinical tests and the KT1000 in the diagnosis of anterior cruciate ligament rupture.British Journal of Sports Medicine, 1991
- The Results of Surgical Repair of Acute Tears of the Posterior Cruciate LigamentPublished by Wolters Kluwer Health ,1991
- Assessing the limits of knee motionThe American Journal of Sports Medicine, 1991
- Genucom, KT-1000, and Stryker knee laxity measuring device comparisonsThe American Journal of Sports Medicine, 1989
- Preoperative instrumented testing of anterior and posterior knee laxityThe American Journal of Sports Medicine, 1989
- Isolated posterior cruciate ligament injuries in athletesThe American Journal of Sports Medicine, 1987
- Acute posterior cruciate ligament injuriesThe American Journal of Sports Medicine, 1981
- Injuries to the Posterior Cruciate LigamentPublished by Wolters Kluwer Health ,1980
- THE POSTERIOR CRUCIATE LIGAMENTPublished by Wolters Kluwer Health ,1967