Design of the Series Resonant Converter for Minimum Component Stress
- 1 July 1986
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. AES-22 (4) , 356-363
- https://doi.org/10.1109/taes.1986.310771
Abstract
For a given output voltage and power, the peak resonant capacitor voltage and peak inductor and switch currents of the series resonant converter depend strongly on the choice of transformer turns ratio and of tank inductance and capacitance. In this paper the particular component values which result in the smallest component stresses are determined, and a simple design strategy is developed. The procedure is illustrated for an off-line 200 W, 5 V application, and it is shown that an incorrect choice of component values can result in significantly higher component stresses than are necessary.Keywords
This publication has 3 references indexed in Scilit:
- Steady-State Analysis of the Series Resonant ConverterIEEE Transactions on Aerospace and Electronic Systems, 1985
- High-Frequency Resonant Transistor DC-DC ConvertersIEEE Transactions on Industrial Electronics, 1984
- A complete DC analysis of the series resonant converterPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1982