Early Dose Assessment Following Severe Radiation Accidents

Abstract
Early treatment of victims of high level acute whole-body x-ray or gamma exposure has been shown to improve their likelihood of survival. However, in such cases, both the magnitude of the exposure and the dosimetry profiles) of the victims) are often not known in detail for days to weeks. A simple dose-prediction algorithm based on lymphocyte kinetics as documented in prior radiation accidents is presented here. This algorithm provides an estimate of dose within the first 8 h following an acute whole-body exposure. Early lymphocyte depletion kinetics after a severe radiation accident follow a single exponential, L(t) = Le−k(D)t, where k(D) is a rate constant, dependent primarily on the average dose, D. Within the first 8 h post-accident, K(D) may be calculated utilizing serial lymphocyte counts. Data from the REACTS Radiation Accident Registry were used to develop a dose-prediction algorithm from 43 gamma exposure cases where both lymphocyte kinetics and dose reconstruction were felt to be reasonably reliable. The inverse relationship D(K) may be modeled by a simple two parameter curve of the form D = a/(1 + b/K) in the range 0 ≤ D ≤ 15 Gy, with fitting parameters (mean ± SD): a = 13.6 ± 1.7 Gy, and b = 1.0 ± 0.20 d−1. Dose estimated in this manner is intended to serve only as a first approximation to guide initial medical management.