Nondiffuse Fatty Change of the Liver: Discerning Pseudotumor on MR Images Enhanced with Ferumoxides—Initial Observations
- 1 November 2000
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 217 (2) , 415-420
- https://doi.org/10.1148/radiology.217.2.r00nv26415
Abstract
To clarify the findings of nondiffuse fatty change of the liver on ferumoxides-enhanced magnetic resonance (MR) images. Of 202 patients who underwent ferumoxides-enhanced MR imaging, eight who had nondiffuse fatty change of the liver at computed tomography (CT) were examined as study subjects. MR imaging findings before and 1 hour after ferumoxides administration were compared with CT findings. Focal fatty areas of the liver showing low attenuation on CT images were depicted as areas of relatively high intensity on the ferumoxides-enhanced T1-weighted images in all patients. On enhanced T2-weighted images, focal fatty change showed relatively high intensity in three and isointensity in one of the four patients. Focal spared areas appearing as areas of relatively high attenuation on CT images were depicted as areas of relatively low intensity on the ferumoxides-enhanced T1- and T2-weighted images in all patients. Although prior reports of hepatic MR imaging with ferumoxides indicated that there is accumulation of ferumoxides within focal fatty areas that are no longer seen after the administration of contrast medium, this study revealed that focal fatty change and focal spared areas of fatty liver may be pseudotumors because of the relatively high intensity of fatty areas of the liver. Radiologists can distinguish these conditions from hepatic tumors by using the opposed-phase gradient-echo sequence or the fat-saturation technique.Keywords
This publication has 40 references indexed in Scilit:
- Liver Imaging With Ferumoxides (Feridex??)Topics in Magnetic Resonance Imaging, 1998
- Diagnosis of liver metastases from colorectal adenocarcinomaActa Radiologica, 1997
- Detection of hepatic metastases: ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography.Radiology, 1996
- Superparamagnetic iron oxide--enhanced versus gadolinium-enhanced MR imaging for differential diagnosis of focal liver lesions.Radiology, 1996
- Hepatic tumors: detection and characterization at 1-T MR imaging enhanced with AMI-25.Radiology, 1994
- Liver metastases: safety and efficacy of detection with superparamagnetic iron oxide in MR imaging.Radiology, 1994
- Liver MR imaging with iron oxides: toward consensus and clinical practice.Radiology, 1994
- Superparamagnetic iron oxide: Detection of focal liver lesions at high‐field‐strength MR imagingJournal of Magnetic Resonance Imaging, 1994
- MR imaging with i.v. superparamagnetic iron oxide: efficacy in the detection of focal hepatic lesions.American Journal of Roentgenology, 1993
- Iron oxide-enhanced MR imaging of the liver and spleen: review of the first 5 years.American Journal of Roentgenology, 1990