Correcting organ motion artifacts in x‐ray CT medical imaging systems by adaptive processing. I. Theory
- 9 August 2001
- journal article
- Published by Wiley in Medical Physics
- Vol. 28 (8) , 1562-1576
- https://doi.org/10.1118/1.1388892
Abstract
X-ray CT scanners provide images of transverse cross sections of the human body from a large number of projections. During the data acquisition process, which usually takes about 1 s, motion effects such as respiration, cardiac motion, and patient restlessness produce artifacts that appear as blurring, doubling, and distortion in the reconstructed images, and may lead to inaccurate diagnosis. To address this problem several processing techniques have been proposed that require a priori knowledge of the motion characteristics. This paper proposes a method, which makes no assumptions about the properties of the motion, to eliminate the motion artifacts. The approach in this paper uses a spatial overlap correlator scheme to accurately track organ motion in computed tomography imaging systems. Then, it is shown that as optimum processing scheme to remove organ motion effects is to apply adaptive interference cancellation (AIC) methods, which treat the output of the spatial overlap correlator as noise interference at the input of the AIC process. Furthermore, an AIC method does not require any kind of periodicity of the motion effects. Synthetic data tests demonstrate the validity of this approach and show that hardware modifications are essential for its implementation in x-ray CT medical imaging systems.Keywords
This publication has 12 references indexed in Scilit:
- Correcting organ motion artifacts in x‐ray CT systems based on tracking of motion phase by the spatial overlap correlator. II. Experimental studyMedical Physics, 2001
- Implementation of adaptive and synthetic-aperture processing schemes in integrated active-passive sonar systemsProceedings of the IEEE, 1998
- Correction of computed tomography motion artifacts using pixel-specific back-projectionIEEE Transactions on Medical Imaging, 1996
- Respiratory compensation in projection imaging using a magnification and displacement modelIEEE Transactions on Medical Imaging, 1996
- Noise normalization technique for beamformed towed array dataThe Journal of the Acoustical Society of America, 1995
- On the convergence behavior of the LMS and the normalized LMS algorithmsIEEE Transactions on Signal Processing, 1993
- Motion artifact correction in MRI using generalized projectionsIEEE Transactions on Medical Imaging, 1991
- Optimum bearing resolution for a moving towed array and extension of its physical apertureThe Journal of the Acoustical Society of America, 1990
- Problems and Pitfalls in the Evaluation of Thoracic Aortic Dissection by Computed TomographyJournal of Computer Assisted Tomography, 1982
- An alternative approach to linearly constrained adaptive beamformingIEEE Transactions on Antennas and Propagation, 1982