Estimation of respiratory volumes from the photoplethysmographic signal. Part 2: a model study
- 1 January 1999
- journal article
- photoplethysmography
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 37 (1) , 48-53
- https://doi.org/10.1007/bf02513265
Abstract
A Windkessel model has been constructed with the aim of investigating the respiratory-volume dependence of the photoplethysmographic (PPG) signal. Experimental studies show a correlation between respiratory volume and the peak-to-peak value of the respiratory-induced intensity variations (RIIV) in the PPG signal. The model compartments are organised in two closed chambers, representing the thorax and the abdomen, and in a peripheral part not directly influenced by respiration. Cardiac pulse and respiration are created by continuous adjustment of the pressures in the affected compartments. Together with the criteria for heart and venous valves, the model is based on a set of 17 differential equations. These equations are solved for varying thoracic and abdominal pressures corresponding to different respiratory volumes. Furthermore, a sensitivity analysis is performed to evaluate the properties of the model. The PPG signals are created as a combination of peripheral blood flow and pressure. From these signals, the respiratory synchronous parts are extracted and analysed. To study some important limitations of the model, respiratory type and rate are varied. From the simulations, it is possible to verify our earlier experimental results concerning the relationship between respiratory volume and the peak-to-peak value of the RIIV signal. An expected decrease in the amplitude of the respiratory signal with increased respiratory rate is also found, which is due to the lowpass characteristics of the vessel system. Variations in the relationship between thoracic and abdominal respiration also affect the RIIV signal. The simulations explain and verify what has been found previously in experimental studies.Keywords
This publication has 18 references indexed in Scilit:
- Estimation of respiratory volumes from the photoplethysmographic signal. Part I: experimental resultsMedical & Biological Engineering & Computing, 1999
- Autonomic Control of Skin Microvessels: Assessment by Power Spectrum of Photoplethysmographic WavesClinical Science, 1996
- Low-frequency variability in the blood volume and in the blood volume pulse measured by photoplethysmographyJournal of Biomedical Optics, 1996
- Model studies of the effects of the thoracic pressure on the circulationAnnals of Biomedical Engineering, 1987
- PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANAESTHESIABritish Journal of Anaesthesia, 1985
- Mathematical Analysis of Cardiovascular FunctionIEEE Transactions on Biomedical Engineering, 1985
- Cardiac assist by intrathoracic and abdominal pressure variations: A mathematical studyMedical & Biological Engineering & Computing, 1984
- Computer studies of systemic and regional blood flow mechanisms during cardiopulmonary resuscitationMedical & Biological Engineering & Computing, 1984
- Cardiac output and related measurements and pressure values in the right heart and associated vessels, together with an analysis of the hemo-dynamic response to the inhalation of high oxygen mixtures in healthy subjects.1958
- Photoelectric Plethysmography of the Fingers and Toes in ManExperimental Biology and Medicine, 1937