Motion Artifacts of the Aorta Simulating Aortic Dissection on Spiral CT
- 1 January 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 23 (1) , 1-6
- https://doi.org/10.1097/00004728-199901000-00001
Abstract
Motion artifacts of the ascending aorta may impair image quality and simulate an intimal flap or a false channel. The purpose of this study is to evaluate the prevalence, amplitude, and extent of motion artifacts of the aorta in spiral CT and to specify the effects of acquisition and reconstruction parameters on these artifacts. One hundred seventy-one thoracic spiral CT examinations were retrospectively analyzed by two reviewers. The analysis sought to determine the presence, location, amplitude, and extent of artifacts of the ascending aorta. Aortic artifacts were detected on spiral CT in 57% of cases. The mean amplitude and mean extent were 4+/-4 and 6+/-7 mm, respectively. Artifacts in the ascending aorta were significantly higher with the 360 degrees linear interpolation (LI) algorithm than with the 180 degrees LI algorithm. The prevalence of motion artifacts on spiral CT is higher in this study than the reported prevalence in incremental CT. However, this higher prevalence is significantly reduced when the 180 degrees LI algorithm is used.Keywords
This publication has 13 references indexed in Scilit:
- Spiral CT artifact that simulates aortic dissection: image reconstruction with use of 180 degrees and 360 degrees linear-interpolation algorithms.Radiology, 1997
- Prevalence of motion artifact simulating aortic dissection on spiral CT using a 180 ° linear interpolation algorithm for reconstruction of the imagesEuropean Radiology, 1997
- Aortic dissection: a comparative study of diagnosis with spiral CT, multiplanar transesophageal echocardiography, and MR imaging.Radiology, 1996
- Aortic MotionJournal of Computer Assisted Tomography, 1995
- Acute aortic dissection: typical and atypical imaging features.RadioGraphics, 1994
- Aortic motion artifact simulating dissection on CT scans: elimination with reconstructive segmented images.American Journal of Roentgenology, 1993
- Motion artifact simulating aortic dissection.American Journal of Roentgenology, 1992
- Motion artifact simulating aortic dissection on CT.American Journal of Roentgenology, 1991
- Streak Artefacts of the Thoracic AortaJournal of Computer Assisted Tomography, 1984
- Problems and Pitfalls in the Evaluation of Thoracic Aortic Dissection by Computed TomographyJournal of Computer Assisted Tomography, 1982