Pressure–Volume Curves and Compliance in Acute Lung Injury
- 1 April 1999
- journal article
- Published by American Thoracic Society in American Journal of Respiratory and Critical Care Medicine
- Vol. 159 (4) , 1172-1178
- https://doi.org/10.1164/ajrccm.159.4.9801088
Abstract
Measuring elastic pressure-volume (Pel-V) curves of the respiratory system and the volume recruited by a positive end-expiratory pressure (PEEP) allows one to study the pressure range over which recruitment occurs in acute lung injury (ALI), and to explain how recruitment affects the compliance. Pel-V curves were measured with the low flow inflation technique in 11 patients mechanically ventilated for ALI. Curve I was recorded during inflation from the volume attained after a prolonged expiration (6 s) at PEEP (9.0 +/- 2.2 cm H2O), and Curve II after expiration to the elastic equilibrium volume at zero end-expiratory pressure (ZEEP). By using the end-expiratory volume of the breaths, the curves were aligned on a common volume axis to determine the effect of a single complete expiration. In each patient, Curve II (from ZEEP) was shifted toward lower volumes than Curve I. The volume shift, probably due to derecruitment, was 205 +/- 100 ml at 15 cm H2O (p < 0.01) and 78 +/- 93 ml at 30 cm H2O (p < 0.01); thus, during inflation from ZEEP, the volume deficit was successively regained over a pressure range up to at least 30 cm H2O. At any pressure, compliance was higher on the curve from ZEEP than from PEEP, by 10.0 +/- 8.7 ml/cm H2O at 15 cm H2O (p < 0.01), and by 5.4 +/- 5.5 at 30 cm H2O (p < 0.01). It is concluded that in ALI, a single expiration to ZEEP leads to lung collapse. High compliance during insufflation from ZEEP indicates that lung recruitment happens far above the lower inflection point of the Pel-V curve.Keywords
This publication has 30 references indexed in Scilit:
- Titration of tidal volume and induced hypercapnia in acute respiratory distress syndrome.American Journal of Respiratory and Critical Care Medicine, 1995
- Effects of Positive End-expiratory Pressure on Alveolar Recruitment and Gas Exchange in Patients with the Adult Respiratory Distress SyndromeAmerican Review of Respiratory Disease, 1991
- Value of static pulmonary compliance in predicting mortality in patients with acute respiratory failureIntensive Care Medicine, 1988
- Pressure-Volume Curve of Total Respiratory System in Acute Respiratory Failure: Computed Tomographic Scan StudyAmerican Review of Respiratory Disease, 1987
- Pulmonary compliance measurement in acute respiratory failureCritical Care Medicine, 1985
- Total Respiratory Pressure-Volume Curves in the Adult Respiratory Distress SyndromeChest, 1984
- The role of total static lung compliance in the management of severe ARDS unresponsive to conventional treatmentIntensive Care Medicine, 1984
- Diagnosis of Causes for Acute Respiratory Distress by Pressure-Volume CurvesChest, 1976
- Optimum End-Expiratory Airway Pressure in Patients with Acute Pulmonary FailureNew England Journal of Medicine, 1975
- Ventilation with end-expiratory pressure in acute lung diseaseJournal of Clinical Investigation, 1972