Why use Finapres or Portapres rather than intraarterial or intermittent non-invasive techniques of blood pressure measurement?
- 1 January 1998
- journal article
- research article
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 22 (1) , 37-43
- https://doi.org/10.3109/03091909809009997
Abstract
In the clinic, blood pressure is measured almost exclusively using non-invasive intermittent techniques, of which the auscultatory (Riva-Rocci/Korotkqff, RRK) and the computerized oscillometric method are most often used. However, both methods only provide a momentary value. In addition, the accuracy is hampered by phenomena such as cuff response and white coat hypertension, thus providing artefactually increased values. The vascular unloading technique of Pendz together with the Physiocal criteria of Wesseling provide reliable, noninvasive and continuous estimates of blood pressure. This technique is thus an alternative to the invasive intra-arterial measurements in many cases, without the risks and ethical questions inherent to invasive measurements. Since the pressure waveform is available continuously, computations such as pulse contour and Modelflow cardiac output, spectral analysis and baroreflex sensitivity provide further information on the dynamics of the cardiovascular system on a beat-to-beat basis, similar to intra-arterial measurements.Keywords
This publication has 12 references indexed in Scilit:
- Survey of Automated Noninvasive Blood Pressure MonitorsJournal of Clinical Engineering, 1994
- Computation of aortic flow from pressure in humans using a nonlinear, three-element modelJournal of Applied Physiology, 1993
- Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.Hypertension, 1993
- Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressureCardiovascular Research, 1990
- Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.Hypertension, 1989
- Continuous non-invasive blood pressure monitoring: reliability of Finapres device during the Valsalva manoeuvreCardiovascular Research, 1988
- Accuracy of auscultatory blood pressure measurement with a long cuff.BMJ, 1987
- INVASIVE V. NON-INVASIVE MEASUREMENT OF ARTERIAL PRESSUREBritish Journal of Anaesthesia, 1985
- Effects of Peripheral Vasoconstriction on the Blood Pressure in the Finger, Measured Continuously by a New Noninvasive Method (The Finapres®)Anesthesiology, 1985
- Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a fingerJournal of Clinical Monitoring and Computing, 1985