Do Standard Monitoring Sites Reflect True Brain Temperature When Profound Hypothermia Is Rapidly Induced and Reversed?
Open Access
- 1 February 1995
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 82 (2) , 344-351
- https://doi.org/10.1097/00000542-199502000-00004
Abstract
Background: Brain temperature is closely approximated by most body temperature measurements under normal anesthetic conditions. However, when thermal autoregulation is overridden, large temperature gradients may prevail. This study sought to determine which of the standard temperature monitoring sites best approximates brain temperature when deep hypothermia is rapidly induced and reversed during cardiopulmonary bypass. Methods: Twenty-seven patients underwent cardiopulmonary bypass and deep hypothermic circulatory arrest in order for each to have a giant cerebral aneurysm surgically clipped. Brain temperatures were measured directly with a thermocouple embedded in the cerebral cortex. Eight other body temperatures were monitored simultaneously with less invasive sensors at standard sites. Results: Brain temperature decreased from 32.6 +/- 1.4 degrees C (mean +/- SD) to 16.7 +/- 1.7 degrees C in 28 +/- 7 min, for an average cerebral cooling rate of 0.59 +/- 0.15 degrees C/min. Circulatory arrest lasted 24 +/- 15 min and was followed by 63 +/- 17 min of rewarming at 0.31 +/- 0.09 degrees C/min. None of the monitored sites tracked cerebral temperature well throughout the entire hypothermic period. During rapid temperature change, nasopharyngeal, esophageal, and pulmonary artery temperatures corresponded to brain temperature with smaller mean differences than did those of the tympanic membrane, bladder, rectum, axilla, and sole of the foot. At circulatory arrest, nasopharyngeal, esophageal, and pulmonary artery mean temperatures were within 1 degree C of brain temperature, even though individual patients frequently exhibited disparate values at those sites. Conclusions: When profound hypothermia is rapidly induced and reversed, temperature measurements made at standard monitoring sites may not reflect cerebral temperature. Measurements from the nasopharynx, esophagus, and pulmonary artery tend to match brain temperature best but only with an array of data can one feel comfortable disregarding discordant readings.Keywords
This publication has 23 references indexed in Scilit:
- Cardiac Performance Preserved Despite Thiopental LoadingAnesthesiology, 1993
- A Comfortable Hypothesis Reevaluated Cerebral Metabolic Depression and Brain Protection during IschemiaAnesthesiology, 1992
- Intracerebral temperature in neurosurgical patientsNeurosurgery, 1991
- Comparing Methods of Measurement: An Alternative ApproachAnesthesiology, 1990
- Determination of Brain Temperatures for Safe Circulatory Arrest during Cardiovascular OperationThe Annals of Thoracic Surgery, 1988
- Small Differences in Intraischemic Brain Temperature Critically Determine the Extent of Ischemic Neuronal InjuryJournal of Cerebral Blood Flow & Metabolism, 1987
- Deep hypothermic circulatory arrest: A review of pathophysiology and clinical experience as a basis for anesthetic managementJournal of Cardiothoracic Anesthesia, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Hypothermia by Extracorporeal Circulation for NeurosurgeryAnesthesia & Analgesia, 1962
- TEMPERATURE GRADIENTS DURING HYPOTHERMIAAnnals of the New York Academy of Sciences, 1959