A review of the composition, characteristics, and effectiveness of barrier mesh prostheses utilized for laparoscopic ventral hernia repair
- 5 September 2011
- journal article
- review article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 26 (2) , 566-575
- https://doi.org/10.1007/s00464-011-1899-3
Abstract
The objective of this review was to provide an overview of the components that comprise each of the eight barrier mesh prostheses commonly utilized for LVHR and to review the current literature related to the characteristics and effectiveness of these materials to guide the general surgeon in selecting the most appropriate material for LVHR. Composite prostheses with permanent barriers (Bard™ Composix™ E/X, Bard™ Composix™ L/P, and DUALMESH® Biomaterial) were compared to composite prostheses with absorbable barriers (C-QUR™ Mesh, PROCEED™ Surgical Mesh, Bard™ Sepramesh™ IP Composite, Parietex™ Composite, and PHYSIOMESH™) using scanning electron microscopy and a review of the current preclinical and clinical literature. Clinical studies and preclinical animal models have attempted to determine the adhesion characteristics and effectiveness of barrier mesh prostheses available for ventral hernia repair applications. However, it is difficult to make any definitive statements about the adhesion characteristics and effectiveness of these materials because all meshes were not included in all studies and likewise not compared under identical conditions. Overall, Parietex™ Composite and DUALMESH® Biomaterial were cited most frequently for improvement of adhesion characteristics, followed closely by Bard™ Sepramesh™ IP Composite and C-QUR™ Mesh. Bard™ Composix™, PROCEED™ Surgical Mesh, and uncoated polypropylene were cited most frequently as having the most tenacious and extensive adhesions. Differences observed between the various barrier prostheses are likely attributable to the chemical composition of the barrier or the conditions required for resorption and metabolism of the barrier components. It is likely that the components of these barriers incite a wide range of inflammatory responses resulting in the range of adhesion coverage and tenacity observed in the preclinical and clinical studies reviewed. Clinical trials are needed to more appropriately define the clinical effectiveness of these barriers.Keywords
This publication has 43 references indexed in Scilit:
- Physicomechanical evaluation of absorbable and nonabsorbable barrier composite meshes for laparoscopic ventral hernia repairSurgical Endoscopy, 2010
- Prospective evaluation of adhesion characteristics to intraperitoneal mesh and adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repairSurgical Endoscopy, 2010
- Visceral adhesions to hernia prosthesesHernia, 2010
- Eighty-five redo surgeries after 733 laparoscopic treatments for ventral and incisional hernia: adhesion and recurrence analysisHernia, 2010
- Subsequent abdominal surgery after laparoscopic ventral and incisional hernia repair with an expanded polytetrafluoroethylene mesh: a single institution experience with 72 reoperationsHernia, 2009
- Degradation of mesh coatings and intraperitoneal adhesion formation in an experimental modelBritish Journal of Surgery, 2009
- 120-Day Comparative Analysis of Adhesion Grade and Quantity, Mesh Contraction, and Tissue Response to a Novel Omega-3 Fatty Acid Bioabsorbable Barrier Macroporous Mesh After Intraperitoneal PlacementSurgical Innovation, 2008
- Comparison of two composite meshes using two fixation devices in a porcine laparoscopic ventral hernia repair modelHernia, 2004
- Resistance to adhesion formation: A comparative study of treated and untreated mesh products placed in the abdominal cavityHernia, 2004
- Dependence of the biodegradability of carboxymethylcellulose on its supermolecular structure and molecular parametersChemistry of Natural Compounds, 1995