Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component
Open Access
- 1 August 2005
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 87 (8) , 1061-1067
- https://doi.org/10.1302/0301-620x.87b8.16161
Abstract
We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d’Aubigné and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6°. The mean linear polyethylene wear was 0.05 mm/year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components.Keywords
This publication has 63 references indexed in Scilit:
- CLINICAL AND RADIOGRAPHIC RESULTS ASSOCIATED WITH A MODERN, CEMENTLESS MODULAR CUP DESIGN IN TOTAL HIP ARTHROPLASTYJournal of Bone and Joint Surgery, 2004
- CLINICAL AND RADIOGRAPHIC ANALYSIS OF THE MALLORY-HEAD FEMORAL COMPONENT IN REVISION TOTAL HIP ARTHROPLASTYJournal of Bone and Joint Surgery, 2003
- Minimal 11-year follow-up of extensively porous-coated stems in femoral revision total hip arthroplastyThe Journal of Arthroplasty, 2002
- Revision of a Cemented Acetabular Component to a Cementless Acetabular ComponentJournal of Bone and Joint Surgery, 2001
- Minimum 10-Year-Results of Extensively Porous-Coated Stems in Revision Hip ArthroplastyClinical Orthopaedics and Related Research, 1999
- Uncemented Revision Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1996
- Hydroxyapatite coating converts fibrous tissue to bone around loaded implantsThe Journal of Bone and Joint Surgery. British volume, 1993
- Bonding of bone to apatite-coated implantsThe Journal of Bone and Joint Surgery. British volume, 1988
- Revision total hip arthroplasty.Journal of Bone and Joint Surgery, 1985
- Revision of Aseptic Loose Total Hip ArthroplastiesClinical Orthopaedics and Related Research, 1982