Sustained Reentry in the Left Ventricle of Fibrillating Pig Hearts
- 21 March 2003
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 92 (5) , 539-545
- https://doi.org/10.1161/01.res.0000061569.23879.20
Abstract
It has been proposed that ventricular fibrillation (VF) is driven by sustained reentry. However, mapping studies have not detected such “mother rotors” in large mammalian hearts. We mapped VF from three 21×12 unipolar electrode arrays in 6 pigs. Two of the arrays were adjacent to each other on the left-ventricular epicardium. Electrode spacing was 2 mm. The third array consisted of 21 needles (0.5-mm diameter, 12 electrodes, 1-mm spacing) inserted in a row (2-mm spacing) between the epicardial arrays. A total of 88 5-second VF epochs were analyzed with automatic reentry detection algorithms. Although intramural reentry was sporadically present (29 total occurrences), it was always short-lived with a mean life span of 127±57 ms. However, in 3 of the 6 animals, sustained epicardial reentry (ie, reentry persisting for more than a few cycles) was consistently present, often lasting for several seconds. For each epoch, we computed indices characterizing (1) the relative duration of reentry on the two epicardial arrays (R), (2) the flow of wavefronts between epicardial arrays (W), and (3) the relative activation rates of the two epicardial arrays (F).Rdid not correlate with eitherWorFindicating that rotor-containing regions did not produce a net outflow of wavefronts and were not faster than neighboring regions. Thus, sustained epicardial, but not intramural, rotors were consistently present in some large animal hearts during VF. However, we found no evidence that these rotors were responsible for sustaining VF through the mechanisms outlined in the mother rotor hypothesis.Keywords
This publication has 15 references indexed in Scilit:
- Fiberglass needle electrodes for transmural cardiac mappingIEEE Transactions on Biomedical Engineering, 2002
- Fibrillation is More Complex in the Left Ventricle than in the Right VentricleJournal of Cardiovascular Electrophysiology, 2000
- Preventing ventricular fibrillation by flattening cardiac restitutionProceedings of the National Academy of Sciences, 2000
- Three-dimensional surface reconstruction and fluorescent visualization of cardiac activationIEEE Transactions on Biomedical Engineering, 2000
- Evolution of the Organization of Epicardial Activation Patterns During Ventricular FibrillationJournal of Cardiovascular Electrophysiology, 1998
- Spatiotemporal complexity of ventricular fibrillation revealed by tissue mass reduction in isolated swine right ventricle. Further evidence for the quasiperiodic route to chaos hypothesis.Journal of Clinical Investigation, 1997
- A quantitative framework for analyzing epicardial activation patterns during ventricular fibrillationAnnals of Biomedical Engineering, 1997
- Electrical alternans and spiral wave breakup in cardiac tissueChaos: An Interdisciplinary Journal of Nonlinear Science, 1994
- Flow of "injury" current and patterns of excitation during early ventricular arrhythmias in acute regional myocardial ischemia in isolated porcine and canine hearts. Evidence for two different arrhythmogenic mechanisms.Circulation Research, 1980
- A computer model of atrial fibrillationPublished by Elsevier ,1964