Analysis of Retrieved Uncemented Porous-Coated Acetabular Components in Patients With and Without Pelvic Osteolysis
- 1 December 2002
- journal article
- research article
- Published by SLACK, Inc. in Orthopedics
- Vol. 25 (12) , 1373-1378
- https://doi.org/10.3928/0147-7447-20021201-15
Abstract
Retrieved polyethylene liners and femoral heads from a consecutive series of revision components of one design were examined. All patients had Long-Term Stable Fixation (OsteoTechnology International, Timonium, Md) total hip arthroplasties (THAs) implanted between 1987 and 1992. The retrieved femoral heads and liners from patients with osteolysis were compared to those without osteolysis. Patients with osteolysis had significantly thinner polyethylene (5.1 mm versus 7.4 mm, P<.01 ) and a higher linear wear rate (0.5 mm/y versus 0.3 mm/y, P=.05). The average femoral head surface roughness also was significantly greater in patients with osteolysis (67 nm versus 35 nm, P<.05). Patients with osteolysis had more total volumetric wear, total linear wear, and volumetric wear rate compared to patients without osteolysis. Age, obesity index, time in situ, and cup inclination were not different between the two groups. Excessive polyethylene wear, probably accelerated by surface roughness of the femoral heads, was associated with pelvic osteolysis in these patients.Keywords
This publication has 43 references indexed in Scilit:
- Long-term results of cemented total hip arthroplasty in patients 45 years old or youngerThe Journal of Arthroplasty, 1994
- Cementless porous-coated anatomic medullary locking total hip prosthesesThe Journal of Arthroplasty, 1994
- Histology of porous-coated acetabular components: 25 cementless cups retrieved after arthroplastyActa Orthopaedica, 1993
- Clinical and radiographic analysis of the uncemented lsf total hip arthroplastyThe Journal of Arthroplasty, 1992
- Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplastyThe Journal of Arthroplasty, 1992
- The Mechanism of Loosening of Cemented Acetabular Components in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1992
- Tissue response in relation to type of wear particles around failed hip arthroplastiesThe Journal of Arthroplasty, 1990
- The Pathology of Failed Total Joint ArthroplastyPublished by Wolters Kluwer Health ,1982
- Reactions of the articular capsule to wear products of artificial joint prosthesesJournal of Biomedical Materials Research, 1977
- Can Wear in Total Hip Arthroplasties Be Assessed from Radio graphs?Published by Wolters Kluwer Health ,1976