Assessment of Resolution and Intercenter Reproducibility of Results of Genotyping Staphylococcus aureus by Pulsed-Field Gel Electrophoresis of Sma I Macrorestriction Fragments: a Multicenter Study
- 1 June 1998
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 36 (6) , 1653-1659
- https://doi.org/10.1128/jcm.36.6.1653-1659.1998
Abstract
Twenty well-characterized isolates of methicillin-resistant Staphylococcus aureus were used to study the optimal resolution and interlaboratory reproducibility of pulsed-field gel electrophoresis (PFGE) of DNA macrorestriction fragments. Five identical isolates (one PFGE type), 5 isolates that produced related PFGE subtypes, and 10 isolates with unique PFGE patterns were analyzed blindly in 12 different laboratories by in-house protocols. In several laboratories a standardized PFGE protocol with a commercial kit was applied successfully as well. Eight of the centers correctly identified the genetic homogeneity of the identical isolates by both the in-house and standard protocols. Four of 12 laboratories failed to produce interpretable data by the standardized protocol, due to technical problems (primarily plug preparation). With the five related isolates, five of eight participants identified the same subtype interrelationships with both in-house and standard protocols. However, two participants identified multiple strain types in this group or classified some of the isolates as unrelated isolates rather than as subtypes. The remaining laboratory failed to distinguish differences between some of the related isolates by utilizing both the in-house and standardized protocols. There were large differences in the relative genome lengths of the isolates as calculated on the basis of the gel pictures. By visual inspection, the numbers of restriction fragments and overall banding pattern similarity in the three groups of isolates showed interlaboratory concordance, but centralized computer analysis of data from four laboratories yielded percent similarity values of only 85% for the group of identical isolates. The differences between the data sets obtained with in-house and standardized protocols could be the experimental parameters which differed with respect to the brand of equipment used, imaging software, running time (20 to 48 h), and pulsing conditions. In conclusion, it appears that the standardization of PFGE depends on controlling a variety of experimental intricacies, as is the case with other bacterial typing procedures.Keywords
This publication has 9 references indexed in Scilit:
- How to Select and Interpret Molecular Strain Typing Methods for Epidemiological Studies of Bacterial Infections: A Review for Healthcare EpidemiologistsInfection Control & Hospital Epidemiology, 1997
- Contribution of a typing method based on IS256 probing of SmaI-digested cellular DNA to discrimination of European phage type 77 methicillin-resistant Staphylococcus aureus strainsJournal of Clinical Microbiology, 1997
- Consensus guidelines for appropriate use and evaluation of microbial epidemiologic typing systemsClinical Microbiology & Infection, 1996
- Inter-centre comparison of pulsed-field gel electrophoresis for the typing of methicillin-resistant Staphylococcus aureusJournal of Medical Microbiology, 1996
- Analysis of the Population Structure of Mycobacterium tuberculosis in Ethiopia, Tunisia, and the Netherlands: Usefulness of DNA Typing for Global Tuberculosis EpidemiologyThe Journal of Infectious Diseases, 1995
- Field-Inversion Gel ElectrophoresisPublished by Springer Nature ,1991
- Southern hybridization analysis of the mecA deletion from methicillin-resistant Staphylococcus aureusBiochemical and Biophysical Research Communications, 1991
- Physical and Genetic Mapping of the Protein A Gene in the Chromosome of Staphylococcus aureus 8325-4Microbiology, 1989
- Separation of yeast chromosome-sized DNAs by pulsed field gradient gel electrophoresisCell, 1984