Quantitative Study of Flow Dependence in NMR Images at Low Flow Velocities
- 1 November 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 10 (6) , 1006-1015
- https://doi.org/10.1097/00004728-198611000-00022
Abstract
A basic theoretical model that describes the effects of flow in and out of the imaging plane in nuclear magnetic resonance (NMR) images, obtained with the standard pulse sequences single spin echo, multiple spin echo, and inversion recovery, is presented. Theoretically calculated signal values are compared with experimental results obtained from single-slice images of a flow phantom for variable flow velocity v as well as for variable echo time and inversion time at flow velocities < 10 mm/s, corresponding to those found in cerebrospinal fluid, in capillary systems, and in smaller veins. The quantitative correspondence between theory and experiment is good in the range of velocities studied and for the imaging parameters used, but discrepancies occur when higher velocities are studied. In addition, flow in a capillary model is demonstrated qualitatively for very low linear flow velocities, < 1 mm/s. It is concluded that the model describes the essentials of the inflow-outflow effect and that this effect can predict the flow dependent of the NMR signal for low flow velocities. Observed differences between model and experiment may be due to effects of flow-induced phase alterations and due to uncertainty in measurements of the relaxation times T1 and T2. The model described here can be extended to suit other types of pulse sequences and to suit multislice imaging. It can also be extended to incorporate flow-induced phase effects.This publication has 8 references indexed in Scilit:
- Multiple field strength in vivo T1 and T2 for cerebrospinal fluid protonsMagnetic Resonance in Medicine, 1986
- Cardiac Gated MR Imaging of Cerebrospinal Fluid FlowJournal of Computer Assisted Tomography, 1985
- MR Imaging of Venous and Arterial Flow by a Selective Saturation-Recovery Spin Echo (SSRSE) MethodJournal of Computer Assisted Tomography, 1985
- MR Velocity Imaging by Phase DisplayJournal of Computer Assisted Tomography, 1985
- Verification and evaluation of internal flow and motion. True magnetic resonance imaging by the phase gradient modulation method.Radiology, 1985
- Derivation of quantitative information in NMR imaging: a phantom studyPhysics in Medicine & Biology, 1984
- Potential problems with selective pulses in NMR imaging systemsMedical Physics, 1984
- Nuclear Magnetic Resonance Blood Flow Measurements in the Human BrainScience, 1983