EVALUATION OF THE SLOPE-VOLUME METHOD AS AN INDEX OF PULMONARY BLOOD VOLUME*
Open Access
- 1 March 1960
- journal article
- research article
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 39 (3) , 466-472
- https://doi.org/10.1172/jci104060
Abstract
Studies were carried out to test the validity of the Newman slope-volume method as an index or measurement of the volume of blood in the lungs. Indocyanine (cardio-green) dye was injected into the pulmonary artery of the dog, and indicator dilution curves were inscribed at the aortic root using a densitometer with a high frequency response. Sampling was from the aorta rather than the left atrium to ensure adequate mixing of the dye with blood. The Stewart-Hamilton method was used to derive the volume of blood in the lungs and chambers of the left side of the heart; the Newman method was used to calculate the slope volume. In 36 determinations in 16 dogs, the volume of blood in the lungs and left side of the heart was 156 ml (SE 3.9) per 10 kg of body weight, whereas the slope volume was 48 ml (Se 1.7) per 10 kg of body weight. Thus, the slope volume is about 30% of the volume in the lungs and left side of the heart and it is probably about 45% of the pulmonary blood volume. With repeated temporary occlusion of the right main pulmonary artery, the volume of blood in the lungs and left side of the heart decreased from an average of 332 to 229 ml, while the average slope volume decreased from 91 to 80 ml. With occlusion of the arteries to the lower half of the right lung, the former volume decreased from 427 to 335 ml, while the latter decreased from 149 to 139 ml. With the assumption that the Stewart-Hamilton method is valid, it appears that the slope volume neither gives a measurement of the volume of blood in the lungs nor reflects the magnitude of changes induced therein.[long dash]Auth. summ.Keywords
This publication has 16 references indexed in Scilit:
- Components of the "Central" Blood Volume in the DogCirculation Research, 1960
- Determination of central blood volume. Comparison of Stewart-Hamilton method with direct measurements in dogsAmerican Journal of Physiology-Legacy Content, 1959
- Relative Effects of Heart Chambers, Lungs, and Mitral Insufficiency on the Shape of Indicator Dilution CurvesCirculation Research, 1959
- SOME FACTORS AFFECTING INDICATOR DILUTION CURVES IN THE PRESENCE AND ABSENCE OF VALVULAR INCOMPETENCEJournal of Clinical Investigation, 1959
- The Measurement of Circulation Time by Means of an IndicatorPhysics in Medicine & Biology, 1958
- THE HEMODYNAMIC EFFECTS OF LARGE ATRIAL SEPTAL DEFECTSJournal of Thoracic Surgery, 1957
- Demonstration of Preferential Flow of Blood From Inferior Vena Cava and From Right Pulmonary Veins Through Experimental Atrial Septal Defects in DogsCirculation Research, 1956
- Mathematical considerations of indicator dilution techniques.1954
- The Influence of Injection Site upon the Form of Dye-Dilution CurvesCirculation Research, 1953
- The Dye Dilution Method for Describing the Central CirculationCirculation, 1951