Validity of fluorescent microspheres method for bone blood flow measurement during intentional arterial hypotension
Open Access
- 1 September 2003
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 95 (3) , 1153-1158
- https://doi.org/10.1152/japplphysiol.00299.2003
Abstract
In this study, we compared bone blood flow values obtained by simultaneously injected fluorescent (FM) and radiolabeled microspheres (RM) at stepwise reduced arterial blood pressure. Ten anesthetized female New Zealand White rabbits received simultaneous left ventricular injections of FM and RM at 90, 70, and 50 mmHg mean arterial blood pressure (MAP). After the experiments, both kidneys and long bones of all four limbs were removed and dissected in a standardized manner. Radioactivity (corrected for decay, background, and spillover) and fluorescence were determined, and blood flow values were calculated. Relative blood flow values estimated for each bone sample by RM and FM were significantly correlated ( r = 0.98, slope = 0.99, and intercept = 0.04 for 90 mmHg; r = 0.98, slope = 0.94, and intercept = 0.09 for 70 mmHg; r = 0.98, slope = 0.96, and intercept = 0.07 for 50 mmHg). Blood flow values (ml · min-1 · 100 g-1) of right and left bone samples determined at the different arterial blood pressures were identical. During moderate hypotension (70 mmHg MAP), blood flow in all bone samples remained unchanged compared with 90 mmHg MAP, whereas a significant decrease of bone blood flow was observed at severe hypotension (50 mmHg MAP). Our results demonstrate that the FM technique is valid for measuring bone blood flow. Differences in bone blood flow during altered hemodynamic conditions can be detected reliably. In addition, changes in bone blood flow during hypotension indicate that vasomotor control mechanisms, as well as cardiac output, play a role in setting bone blood flow.Keywords
This publication has 37 references indexed in Scilit:
- Determination of Regional Bone Blood Flow by Means of Fluorescent Microspheres Using an Automated Sample-Processing ProcedureEuropean Surgical Research, 2003
- Selective reduction of bone blood flow by short-term treatment with high-dose methylprednisoloneThe Journal of Bone and Joint Surgery. British volume, 2001
- Use of an automated fluorescent microsphere method to measure regional blood flow in the fetal lambCanadian Journal of Physiology and Pharmacology, 1997
- Use of an automated fluorescent microsphere method to measure regional blood flow in the fetal lambCanadian Journal of Physiology and Pharmacology, 1997
- Blood flow and mechanical properties of healing boneActa Orthopaedica, 1992
- Arteriovenous shunting is not associated with venous congestion in bone: Knee tamponade studied with 15-μm and 50-μm microspheres in immature dogsActa Orthopaedica, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Blood flow in rabbit osteotomies studied with radioactive microspheresActa Orthopaedica, 1984
- Determination of Cortical Blood Flow in Rabbit Femur by Radioactive MicrospheresActa Physiologica Scandinavica, 1970
- Hemodynamics of the Bone Marrow CirculationActa Physiologica Scandinavica, 1968