Abstract
This paper describes a non-destructive measuring method to locate small discharges in shielded plastics insulated high voltage cables. The sensitivity is so high that even discharges less than 5 pC can be located in long lengths of cable (> 1000 m).

This publication has 3 references indexed in Scilit: