Reduction of some selected spectral interferences in inductively coupled plasma mass spectrometry
- 1 January 1994
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 9 (9) , 1015-1020
- https://doi.org/10.1039/ja9940901015
Abstract
The reduction of spectral interferences has been investigated and both aerosol desolvation and the utilization of high mass resolution have been applied in order to improve detection limits for V, Cr, Ga, Ge and As, which are subject to interferences by polyatomic ions in solutions containing Cl. Experiments with a laboratory-made quadrupole ICP-MS have been performed in order to optimize the desolvation parameters. Ion signals corresponding to CIO+ and CIOH+ are reduced by more than one order of magnitude if appropriate heating and cooling temperatures are chosen. A reduction in polyatomic ions like CIO2 +, CI2 + and ArCI+ by using desolvation was also observed. With the prototype of a new double-focusing ICP-MS system from Finnigan MAT, Bremen, Germany, operated in the low resolution mode, the detection limits with desolvation have been determined and were found to be up to 2 orders of magnitude lower compared with measurements without desolvation. The detection limit (3s) for V in 0.4 mol l–1 HCl was reduced from 25 to 1 ng ml–1. High mass resolution improved the detection limits for V, Cr and Ga in HCl by up to 4 orders of magnitude compared with measurements in the low resolution mode (2 pg ml–1 for V in 0.4 mol 1–1 HCl), and lowest detection limits have been obtained with the combination of desolvation and high mass resolution (0.6 pg ml–1 for V in 0.4 mol l–1 HCl).Keywords
This publication has 25 references indexed in Scilit:
- Measurement of vanadium, nickel, and arsenic in seawater and urine reference materials by inductively coupled plasma mass spectrometry with cryogenic desolvationAnalytical Chemistry, 1993
- Diagnostic investigations of aerosols with varying water content in inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1993
- Anion exchange for the determination of arsenic and selenium by inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1993
- Argon inductively coupled plasma mass spectrometry with thermospray, ultrasonic, and pneumatic nebulizationAnalytical Chemistry, 1991
- Direct injection nebulization for inductively coupled plasma mass spectrometryAnalytical Chemistry, 1991
- Studies with desolvation in inductively coupled plasma-mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1990
- Separation of trace metal complexes for analysis of samples of high salt content by inductively coupled plasma mass spectrometryAnalytical Chemistry, 1989
- Study of plasma potential effects in a 40 MHz inductively coupled plasma mass spectrometry systemSpectrochimica Acta Part B: Atomic Spectroscopy, 1989
- Study of the influence of water vapour loading and interface pressure in inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1988
- A method for investigating size distributions of aqueous droplets in the range 0.5–10 μm produced by pneumatic nebulizersSpectrochimica Acta Part B: Atomic Spectroscopy, 1980