Effect of Electrical Stimulation on the Tensile Strength of the Porous Implant and Bone Interfac
- 1 January 1975
- journal article
- research article
- Published by Taylor & Francis in Biomaterials, Medical Devices, and Artificial Organs
- Vol. 3 (2) , 233-243
- https://doi.org/10.3109/10731197509118624
Abstract
The effect of electrical stimulation upon the direct tensile strength of the interfacial union between porous calcium aluminate implants (100 to 200 mu diameter pores) and bone was studied in the femurs of rabbits. After about 4 weeks of implantation the tnesile strength of the electrically stimulated specimens was approximately two times that of the nonstimulated ones. This indicates that electrical stimulation increased the rate of new bone formation under the experimental conditions.Keywords
This publication has 16 references indexed in Scilit:
- Attachment of prostheses to the musculo‐skeletal system by tissue ingrowth and mechanical interlockingJournal of Biomedical Materials Research, 1973
- Biomechanical investigations of bone-porous carbon and porous metal interfacesJournal of Biomedical Materials Research, 1973
- In vivo and in vitro changes in strength of orthopedic calcium aluminatesJournal of Biomedical Materials Research, 1973
- Electric Enhancement of Bone HealingScience, 1972
- Augmentation of Regenerative Healing in ManPublished by Wolters Kluwer Health ,1972
- Application of porous ceramics for the attachment of load bearing internal orthopedic applicationsJournal of Biomedical Materials Research, 1971
- HEALING OF NONUNION OF THE MEDIAL MALLEOLUS BY MEANS OF DIRECT CURRENTPublished by Wolters Kluwer Health ,1971
- Preliminary evaluation of porous metal surfaced titanium for orthopedic implantsJournal of Biomedical Materials Research, 1970
- Experimental Model for Studying the Effect of Electric Current on Bone in vivoNature, 1969
- Piezoelectric Effect in BoneNature, 1963