Functional magnetic resonance imaging (fMRI) is a widely used technique for generating images or maps of human brain activity. The applications of the technique are widespread in cognitive neuroscience and it is hoped they will eventually extend into clinical practice. The activation signal measured with fMRI is predicated on indirectly measuring changes in the concentration of deoxyhaemoglobin which arise from an increase in blood oxygenation in the vicinity of neuronal firing. The exact mechanisms of this blood oxygenation level dependent (BOLD) contrast are highly complex. The signal measured is dependent on both the underlying physiological events and the imaging physics. BOLD contrast, although sensitive, is not a quantifiable measure of neuronal activity. A number of different imaging techniques and parameters can be used for fMRI, the choice of which depends on the particular requirements of each functional imaging experiment. The high–speed MRI technique, echo–planar imaging provides the basis for most fMRI experiments. The problems inherent to this method and the ways in which these may be overcome are particularly important in the move towards performing functional studies on higher field MRI systems. Future developments in techniques and hardware are also likely to enhance the measurement of brain activity using MRI.Keywords
This publication has 111 references indexed in Scilit:
- The Critical Relationship between the Timing of Stimulus Presentation and Data Acquisition in Blocked Designs with fMRINeuroImage, 1999
- The Effect of Slice Order and Thickness on fMRI Activation Data Using Multislice Echo-Planar ImagingNeuroImage, 1999
- Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its SubtractionNeuroImage, 1998
- Event-Related fMRI: Characterizing Differential ResponsesNeuroImage, 1998
- Mechanism and echo time dependence of the fast response in FMRMagnetic Resonance in Medicine, 1997
- Movement‐Related effects in fMRI time‐seriesMagnetic Resonance in Medicine, 1996
- Functional imaging of the motor systemCurrent Opinion in Neurobiology, 1994
- High-resolution echo-planar imaging at 3.0 TMagnetic Resonance Materials in Physics, Biology and Medicine, 1994
- Functional MRI of human brain activation at high spatial resolutionMagnetic Resonance in Medicine, 1993
- Functional Mapping of the Human Visual Cortex by Magnetic Resonance ImagingScience, 1991