Pseudomonas Species Bacteremia Caused by Contaminated Normal Human Serum Albumin
- 1 May 1977
- journal article
- research article
- Published by Oxford University Press (OUP) in The Journal of Infectious Diseases
- Vol. 135 (5) , 729-735
- https://doi.org/10.1093/infdis/135.5.729
Abstract
In May and June 1973, 11 patients on the surgical service at the University of Maryland Hospital had bacteremia caused by Pseudomonas species. Seven of the isolates recovered from blood cultures had the same antibiogram (sensitive only to chloramphenicol and tetracycline). Ten of the II patients were given 25% normal serum albumin (human) shortly before the onset of symptoms. In contrast, only two of seven patients with bacteremia due to Pseudomonas aeruginosa in May and June (P = 0.013) and only nine of 20 patients located in surgical special care units during these months (P = 0.014) were given this product. When cultured, the albumin in one of 54 previously unopened vials from the implicated lot yielded Pseudomonas cepacia sensitive only to chloramphenicol, tetracycline, and nalidixic acid. Subsequent investigation showed that five more patients in four other hospitals had symptoms of bacteremia shortly after the infusion of different lots of albumin from the same manufacturer, and in four cases P. cepacia was cultured from the suspect albumin. Since sterility testing by manufacturers may not detect low-frequency contamination, surveillance of nosocomial infections, investigation of un usual disease clusters, and prompt reponing of suspect reactions are essential in the control of such outbreaks.Keywords
This publication has 5 references indexed in Scilit:
- Nationwide epidemic of septicemia caused by contaminated intravenous productsThe American Journal of Medicine, 1976
- Pressure Transducers as a Source of Bacteremia after Open Heart SurgeryChest, 1976
- Pseudomonas cepacia in an Intensive Care NurseryPediatrics, 1976
- Sepsis Caused by Contaminated Intravenous FluidsAnnals of Internal Medicine, 1972
- ANTIBIOTIC SUSCEPTIBILITY TESTING BY A STANDARDIZED SINGLE DISK METHOD1966