Quantitative Changes In T-Cell Populations After Left Ventricular Assist Device Implantation : Relationship to T-Cell Apoptosis and Soluble CD95
- 9 November 1999
- journal article
- Published by Wolters Kluwer Health in Circulation
- Vol. 100 (Supplement) , II-211-211
- https://doi.org/10.1161/01.cir.100.suppl_2.ii-211
Abstract
Background—Left ventricular assist devices (LVADs) are currently being evaluated as permanent therapy for end-stage heart failure. Because life-threatening infections limit successful long-term device implantation, we investigated the relationship between quantitative T-cell defects in LVAD recipients and CD95-mediated T-cell apoptosis. Methods and Results—Immunological studies were performed in NYHA class IV patients awaiting cardiac transplantation who received either a TCI Heartmate left ventricular assist device (LVAD) or medical management. Fluorochrome-labeled Mabs were used in T-cell phenotypic analyses. T-cell apoptosis was measured by annexin V binding of T cells cultured in medium for 24 hours. Circulating serum levels of soluble CD95 were measured by ELISA. LVAD recipients had a relative lymphopenia and reduction in CD4 T-cell levels compared with NYHA class IV heart failure controls. These observations were confirmed in a longitudinal study in LVAD recipients, which showed that device implantation was accompanied by progressive and sustained reductions in circulating CD4 T-cell levels. These abnormalities in LVAD recipients were accompanied by increased levels of circulating soluble CD95 and by excessive CD4 and CD8 T-cell apoptosis. Susceptibility to induction of apoptosis was >2-fold greater for CD4 T cells than for CD8 T cells. Conclusions—These results suggest that the reduction in CD4 T-cell levels accompanying LVAD implantation is a consequence of an augmented pathway of CD95-mediated apoptosis. The clinical consequences of these abnormalities may include increased prevalence of systemic infections.Keywords
This publication has 30 references indexed in Scilit:
- Preformed IgG Antibodies Against Major Histocompatibility Complex Class II Antigens Are Major Risk Factors for High-grade Cellular Rejection in Recipients of Heart TransplantationCirculation, 1998
- Clinical impact of infections in left ventricular assist device recipients: The importance of site and organismTransplantation Proceedings, 1997
- Factors Influencing HLA Sensitization in Implantable LVAD RecipientsThe Annals of Thoracic Surgery, 1997
- Bridge Experience With Long-term Implantable Left Ventricular Assist DevicesCirculation, 1997
- Infectious Complications in Left Ventricular Assist Device RecipientsClinical Infectious Diseases, 1997
- Selective cleavage of nuclear autoantigens during CD95 (Fas/APO-1)-mediated T cell apoptosis.The Journal of Experimental Medicine, 1996
- Surface blebs on apoptotic cells are sites of enhanced procoagulant activity: implications for coagulation events and antigenic spread in systemic lupus erythematosus.Proceedings of the National Academy of Sciences, 1996
- Implantable LVAD infections: Implications for permanent use of the deviceThe Annals of Thoracic Surgery, 1996
- Fungal Infections in Left Ventricular Assist Device RecipientsAsaio Journal, 1995
- Prevalence and mortality rate of congestive heart failure in the United StatesJournal of the American College of Cardiology, 1992