Which thermometer? Factors influencing best choice for intermittent clinical temperature assessment
- 1 January 2006
- journal article
- review article
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 30 (4) , 199-211
- https://doi.org/10.1080/03091900600711464
Abstract
The objectives of this study are (a) to review the current technologies, (b) to examine comparative costing data for six selected representative devices, and (c) to discuss the clinical factors related to selection of devices for intermittent temperature measurement. Financial estimates indicate that mercury-in-glass thermometers are the cheapest devices. Compact electronic and chemical (phase change) thermometers are cheaper alternatives than multi-patient contact thermometers requiring probe covers and infrared sensing models, which are commonly adopted in hospitals and clinical practice. However, time required to obtain readings will influence overall costs. Rigorous independent clinical research studies are now needed to establish which of these alternative technologies are ‘fit for purpose’. As a minimum they should offer comparable clinical accuracy and reliability to mercury-in-glass and be suitable for most clinical measurement situations. Furthermore any additional costs should bring demonstrable benefits to the patient, user and healthcare system.Keywords
This publication has 14 references indexed in Scilit:
- The historical development of thermometry and thermal imaging in medicineJournal of Medical Engineering & Technology, 2006
- Reliability of an infrared forehead skin thermometer for core temperature measurementsJournal of Medical Engineering & Technology, 2006
- Current practice and knowledge of nurses regarding patient temperature measurementJournal of Medical Engineering & Technology, 2006
- Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison studyBMC Nursing, 2003
- Infrared ear thermometry compared with rectal thermometry in children: a systematic reviewThe Lancet, 2002
- Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room settingInternational Journal of Pediatric Otorhinolaryngology, 2002
- Normal oral, rectal, tympanic and axillary body temperature in adult men and women: a systematic literature reviewScandinavian Journal of Caring Sciences, 2002
- Comparison of Rectal, Axillary, and Forehead TemperaturesArchives of Pediatrics & Adolescent Medicine, 1996
- Determination of Normal Ear Temperature with an Infrared Emission Detection ThermometerAnnals of Emergency Medicine, 1995
- Axillary and rectal temperature measurements in infants.Archives of Disease in Childhood, 1992