Repeatability of a rapid dosimetric method for methacholine challenge using a pocket turbine spirometer for FEV measurements1
- 1 July 1996
- journal article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 16 (4) , 353-359
- https://doi.org/10.1111/j.1475-097x.1996.tb00724.x
Abstract
The repeatability of a rapid dosimetric method for methacholine challenge was evaluated with 11 asthmatic patients. A Spira Elektro 2 dosimeter was used for methacholine delivery and a pocket turbine spirometer (Micro Spirometer) for FEV1 measurements. Methacholine was delivered in four successive, increasing doses ranging from 80 micrograms up to a cumulative dose of 6900 micrograms. The single determination standard deviation was low (12.5%), corresponding to a 95% confidence interval of +/- 0.925 doubling doses. The mean difference (+/- SE) between measurements of log PD20 FEV1 was -0.015 (0.056), and the absolute value of the difference in log PD20 FEV1 was not significantly related to the average log PD20 FEV1 (r = -0.155, P = 0.65). The rapid dosimetric methacholine challenge test, performed with a pocket turbine spirometer, proved to be as reproducible as previous methods. Furthermore, this methacholine challenge is clearly less time consuming than conventional provocations, including bronchodilator aerosol (given to resolve post-challenge bronchoconstriction); the whole test can be performed in 20 min. This is especially valuable in epidemiologic studies, as well as in clinical practice.Keywords
This publication has 15 references indexed in Scilit:
- Comparison of two epidemiological protocols for measuring airway responsiveness and allergic sensitivity in adultsEuropean Respiratory Journal, 1994
- Accuracy and repeatability of a pocket turbine spirometer: comparison with a rolling seal flow‐volume spirometerClinical Physiology and Functional Imaging, 1993
- A Survey of the Current Use and Methods of Analysis of Bronchoprovocational ChallengesChest, 1991
- Statistics in respiratory medicine. 2. Repeatability and method comparison.Thorax, 1991
- Intrasubject Between-Day Variability of PD20 Methacholine Assessed by the Dosimeter Inhalation TestChest, 1989
- Methacholine bronchial challenge using a dosimeter with controlled tidal breathing.Thorax, 1988
- Comparison of histamine and methacholine for use in bronchial challenge tests in community studies.Thorax, 1988
- Measurement of FEV1 and FVCAnaesthesia, 1988
- Histamine challenge testing: comparison of three methods.Thorax, 1986
- A Screening Test for Airways ReactivityChest, 1982