Mechanistic comparison of blood undergoing laser photocoagulation at 532 and 1,064 nm
- 9 February 2005
- journal article
- research article
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 36 (2) , 155-165
- https://doi.org/10.1002/lsm.20134
Abstract
Background and Objectives We seek to compare and contrast the mechanisms of blood photocoagulation under 532 and 1,064 nm laser irradiation in vitro in order to better understand the in vivo observations. We also seek to validate a finite element model (FEM) developed to study the thermodynamics of coagulation. Study Design/Materials and Methods We study the photocoagulation of whole blood in vitro at 532 and 1,064 nm using time-domain spectroscopic and optical coherence tomography (OCT)-based imaging techniques. We model the coagulation using an FEM program that includes the latent heat of vaporization (LHV) of water, consideration of the pulse shape of the laser, and the bathochromic shift in the hemoglobin absorption spectrum. Results We find significant similarities in the spectroscopic, chemical, and structural changes occurring in hemoglobin and in the blood matrix during photocoagulation despite the very large difference in the absorption coefficients. The more uniform temperature profile developed by the deeper-penetrating 1,064 nm laser allows us to resolve the structural phase transition in the red blood cells (going from biconcave disc to spherocyte) and the chemical transition creating met-hemoglobin. We find that the RBC morphology transition happens first, and that the met-Hb transition happens at a much higher temperature ( > 90°C) than is found in slow bath heating. The FEM analysis with the LHV constraint and bathochromic shift predicts accurately the imaging results in both cases, and can be used to show that at 1,064 nm there is the potential for a runaway increase in absorption during the laser pulse. Conclusions Photothermally mediated processes dominate the in vitro coagulation dynamics in both regimes despite the difference in absorption coefficients. There is a significant risk under 1,064 nm irradiation of vascular lesions in vivo that the dynamic optical properties of blood will cause runaway absorption and heating. This may in turn explain some recent results at this wavelength where full-thickness burns resulted from laser treatment. Lasers Surg. Med. 36:155–165, 2005.Keywords
This publication has 42 references indexed in Scilit:
- Oxygen Saturation-Dependent Absorption and Scattering of BloodPhysical Review Letters, 2004
- Chemical and Structural Changes in Blood Undergoing Laser Photocoagulation¶Photochemistry and Photobiology, 2004
- Thermal analysis of blood undergoing laser photocoagulationIEEE Journal of Selected Topics in Quantum Electronics, 2001
- Predicting the Influence of Compressibility and Thermal and Flow Distribution Asymmetry on the Frequency-Response Characteristics of Multitube Two-Phase Condensing Flow SystemsJournal of Heat Transfer, 1999
- Optical Absorption of Blood Depends on Temperature during a 0.5 ms Laser Pulse at 586 nmPhotochemistry and Photobiology, 1998
- A new optimal wavelength for treatment of port wine stains?Physics in Medicine & Biology, 1995
- Wavelengths for laser treatment of port wine stains and telangiectasiaLasers in Surgery and Medicine, 1995
- Spectrophotometry of Human Hemoglobin in the near Infrared Region from 1000 to 2500 nmJournal of Near Infrared Spectroscopy, 1994
- Selective Photothermolysis: Precise Microsurgery by Selective Absorption of Pulsed RadiationScience, 1983
- Multispot laser photocoagulation system using a fiber bundle scannerApplied Optics, 1982