Control of pH in a System of Flowing Solution Culture using a Microcomputer

Abstract
A system is described which uses a microcomputer to control pH in flowing solution culture and a brief account is given of its performance when intact perennial ryegrass (Lolium perenne L.) plants were grown in nutrient solutions with pH controlled at 5.0, 5.5, 6.0 and 7.0.