Xenon Has Greater Inhibitory Effects on Spinal Dorsal Horn Neurons than Nitrous Oxide in Spinal Cord Transected Cats
- 1 April 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 88 (4) , 893-897
- https://doi.org/10.1097/00000539-199904000-00038
Abstract
Xenon (Xe) suppresses wide dynamic range neurons in cat spinal cord to a similar extent as nitrous oxide (N2O). The antinociceptive action of N2O involves the descending inhibitory system. To clarify whether the descending inhibitory system is also involved in the antinociceptive action of Xe, we compared the effects of Xe on the spinal cord dorsal horn neurons with those of N2O in spinal cord-transected cats anesthetized with alpha-chloralose and urethane. We investigated the change of wide dynamic range neuron responses to touch and pinch by both anesthetics. Seventy percent Xe significantly suppressed both touch- and pinch-evoked responses in all 12 neurons. In contrast, 70% N2O did not show significant suppression in touch- and pinch-evoked responses. These results suggest that the antinociceptive action of Xe might not be mediated by the descending inhibitory system, but instead may be produced by the direct effect on spinal dorsal horn neurons. Xenon (Xe) is an inert gas with anesthetic properties. We examined the antinociceptive effects of Xe and nitrous oxide (N2O) in spinal cord-transected cats. Our studies indicate that Xe has a direct antinociceptive action on the spinal cord that is greater than that of N2O.Keywords
This publication has 21 references indexed in Scilit:
- The Effect of Xenon on Spinal Dorsal Horn NeuronsAnesthesia & Analgesia, 1997
- Priming of Anesthesia Circuit with Xenon for Closed Circuit AnesthesiaArtificial Organs, 1997
- Antinociceptive Response to Nitrous Oxide Is Mediated by Supraspinal Opiate and Spinal α2Adrenergic Receptors in the RatAnesthesiology, 1996
- Anaesthesia and the ‘Inert’ Gases with Special Reference to XenonAnaesthesia and Intensive Care, 1992
- A Minimal-flow System for Xenon AnesthesiaAnesthesiology, 1991
- Safety and efficacy of xenon in routine use as an inhalational anaestheticThe Lancet, 1990
- Nitrous Oxide Activates the Supraspinal Pain Inhibition SystemActa Anaesthesiologica Scandinavica, 1981
- Anesthetics as tEratogens: Nitrous Oxide Is Fetotoxic, Xenon Is NotScience, 1980
- SOLUBILITY COEFFICIENTS FOR INHALED ANAESTHETICS FOR WATER, OIL AND BIOLOGICAL MEDIABritish Journal of Anaesthesia, 1973
- Observations on the Anesthetic Effect of the Combination of Xenon and HalothaneAnesthesiology, 1969