The aim of this study was 1) to investigate the validity of repeated estimations of blood flow using colored microspheres (CMS) and 2) to develop and validate a method that permits four consecutive estimations in the same animal using nonradiolabeled microspheres (NRMS). Several mixtures of different types of microspheres were injected in dogs, with each mixture containing the radiolabeled microspheres (RMS; labeled with113Sn) with either three CMS, four CMS, or three CMS and one type of fluorescent (crimson labeled) microsphere (FMS). The blood flows estimated with the use of any of the injected microspheres were compared with those measured using the RMS as the “gold standard.” The results were analyzed by 1) regression analysis, 2) variance analysis (ANOVA I), and 3) estimation of the limits of agreement between RMS and NRMS flow rates. The results indicate that simultaneous estimations of blood flow obtained with the use of more than three CMS lack accuracy and reliability. A combination of three types of CMS with crimson-labeled FMS, however, offers the possibility to estimate consecutively four different flow rates in the same animal in an accurate way and with relatively high precision.Keywords
This publication has 9 references indexed in Scilit:
- Validation of fluorescent-labeled microspheres for measurement of regional organ perfusionJournal of Applied Physiology, 1993
- Recovery of regional contractile function and oxidative metabolism in stunned myocardium induced by 1-hour circumflex coronary artery stenosis in chronically instrumented dogs.Circulation Research, 1993
- Direct comparison of [13N]ammonia and [15O]water estimates of perfusion with quantification of regional myocardial blood flow by microspheres.Circulation, 1993
- Measurement of regional myocardial blood flow with multiple colored microspheres.Circulation, 1991
- Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs.Circulation, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- The microsphere method facilitates statistical assessment of regional blood flowBasic Research in Cardiology, 1985
- The radioactive microsphere method for the assessment of regional myocardial blood flow after coronary artery occlusionPflügers Archiv - European Journal of Physiology, 1975
- Some sources of error in measuring regional blood flow with radioactive microspheres.Journal of Applied Physiology, 1971