Rapid and economical method for species identification of clinically significant coagulase-negative staphylococci
- 1 May 1995
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 33 (5) , 1060-3
- https://doi.org/10.1128/jcm.33.5.1060-1063.1995
Abstract
Four methods for the species identification of coagulase-negative staphylococci in the medical microbiology laboratory were compared with 444 consecutive isolates. The methods included (i) the reference method based on growth tests, (ii) API ID 32 Staph (bioMérieux), (iii) Staph-Zym (Rosco), and (iv) a rapid 4-h method developed in our laboratory (UZA method). The last method is based on the detection within 4 h of enzymatic activity of heavy bacterial suspensions in three substrate solutions (nongrowth tests). For 16.5% of the isolates some supplementary growth tests read after 24 h had to be added to the enzyme data for satisfactory identification. The reference method failed to identify four isolates. Of the 440 isolates identified by the reference method, API ID 32 Staph, Staph-Zym, and the UZA method correctly identified 419 (95.2%), 429 (97.5%), and 430 (97.7%) and misidentified 8 (1.8%), 4 (0.9%), and 1 (0.2%), respectively. Staphylococcus epidermidis, S. haemolyticus, S. lugdunensis, S. schleiferi, and S. capitis were identified with an accuracy of 98 to 100% by all the systems tested. S. capitis subsp. ureolyticus was not recognized by the API ID 32 system because the biochemical profiles for it are not yet included in the corresponding database. Whereas API ID 32 identified all 13 S. warneri isolates, both Staph-Zym and the UZA method missed 2 of these. S. hominis was identified with the least accuracy by the API ID 32 system (26 of 39 isolates), whereas the UZA and Staph-Zym methods identified 36 of the isolates belonging to this species. The UZA method did not identify any of the S. cohnii, S. xylosus, S. lentus, and S. sciuri strains, since it included no discriminatory tests for these species, because they are extremely rarely found in humans. Of all 440 isolates tested, the UZA method failed to identify 9 and misidentified 1 other. Eighty-one percent of the isolates were identified within 4 h and 97.7% were identified after 24 h, at considerably less expense than by the API ID 32 Staph and Staph-Zym methods.Keywords
This publication has 14 references indexed in Scilit:
- Coagulase-Negative Staphylococci: Pathogens Associated with Medical ProgressClinical Infectious Diseases, 1994
- Update on clinical significance of coagulase-negative staphylococciClinical Microbiology Reviews, 1994
- Endocarditis Due to Staphylococcus lugdunensis: Report of 11 Cases and ReviewClinical Infectious Diseases, 1993
- Native valve endocarditis caused byStaphylococcus capitisEuropean Journal of Clinical Microbiology & Infectious Diseases, 1993
- Staphylococcus schleiferi: A New Opportunistic PathogenClinical Infectious Diseases, 1993
- Comparative Evaluation of the Rapid Id 32A Kit System, Miniaturized Standard Procedure and a Rapid Fermentation Procedure for the Identification of Anaerobic BacteriaActa Clinica Belgica, 1993
- Clinically significant coagulase-negative staphylococci: identification and resistance patternsJournal of Hospital Infection, 1992
- Automated systems for identification of microorganismsClinical Microbiology Reviews, 1992
- Rapid conventional scheme for biochemical identification of antibiotic resistant enterobacteriaceae isolates from urine.Journal of Clinical Pathology, 1988
- Laboratory, clinical, and epidemiological aspects of coagulase-negative staphylococciClinical Microbiology Reviews, 1988