Balloon angioplasty with stent implantation in experimental coarctation of the aorta.
Open Access
- 1 June 1994
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation
- Vol. 89 (6) , 2677-2683
- https://doi.org/10.1161/01.cir.89.6.2677
Abstract
BACKGROUND Balloon angioplasty of coarctation of the aorta is an effective method of treatment but is complicated by tearing of the aortic intima, formation of aneurysms, and restenosis. Stent placement at the time of balloon dilation could prevent restenosis and could also prevent progression of intimal tears to aneurysms. The purpose of this study was to evaluate the feasibility of balloon dilation and implantation of balloon-expandable stents in an experimental model of coarctation and to examine the effect of stent placement at the site of surgically created stenosis. METHODS AND RESULTS Coarctation of the aorta was surgically produced in 11 juvenile swine. Simultaneous coarctation angioplasty and stent implantation was performed in 10 animals 34 +/- 7.8 days after surgery. Repeat catheterization was performed 59 +/- 6 days after stent implantation. Five animals underwent reexpansion of stents with subsequent follow-up catheterization. Aortic specimens were examined by light microscopy and scanning electron microscopy. Coarctation angioplasty with stent implantation was successful in all, with an increase in coarctation diameter from 46 +/- 8.5% to 90 +/- 12.2% of proximal aortic diameter (P = .0001). Systolic pressure gradient decreased from 32 +/- 19.8 to 0.5 +/- 2.8 mm Hg (P < .001). All stents were patent at follow-up catheterization, with no evidence of intraluminal thrombosis. Reexpansion in five animals increased the stent diameter from a mean of 77.4 +/- 12.1% to 93 +/- 11.0% of proximal aortic diameter (P = .02). Gross examination of aortic specimens demonstrated formation of neointima over the stent wherever the stent struts were in contact with the aortic wall. The stent occupied a subintimal position and produced minimal compression of the underlying media. Medial compression was noted immediately beneath stent struts, but there was no evidence of intimal or medial dissection. CONCLUSIONS Balloon angioplasty with simultaneous implantation of balloon-expandable stents is effective in relieving aortic obstruction in experimental coarctation. Reexpansion of the rigid stent can be performed in an area of surgical aortotomy and coarctation without significant intimal or medial injury. Stent implantation may be useful in preventing restenosis and aneurysm formation after angioplasty of coarctation.Keywords
This publication has 11 references indexed in Scilit:
- Re-expansion of balloon-expandable stents after growthPublished by Elsevier ,2010
- Balloon expandable intravascular stents: Aortic implantation and late further dilation in growing minipigsAmerican Heart Journal, 1993
- Balloon coarctation angioplasty in adolescents and adults: Early and intermediate resultsAmerican Heart Journal, 1992
- Surgical repair is safe and effective after unsuccessful balloon angioplasty of native coarctation of the aortaJournal of the American College of Cardiology, 1992
- Placement of Balloon-expandable Intraluminal Stents in Iliac Arteries: First 171 ProceduresRadiology, 1990
- Causes of recoarctation after balloon angioplasty of unoperated aortic coarctationJournal of the American College of Cardiology, 1989
- Intraluminal stents in atherosclerotic iliac artery stenosis: preliminary report of a multicenter study.Radiology, 1988
- Balloon dilation of unoperated coarctation of the aorta: Short- and intermediate-term resultsJournal of the American College of Cardiology, 1988
- Percutaneous balloon angioplasty for native coarctation of the aortaJournal of the American College of Cardiology, 1987
- Transluminal balloon coarctation angioplasty: Experience with 27 patientsThe American Journal of Cardiology, 1984