Universal Response in Liquid Chromatography Using Charged Aerosol Detection
- 28 March 2006
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (9) , 3186-3192
- https://doi.org/10.1021/ac060078j
Abstract
A new, empirical approach is introduced to correct for the varying response of aerosol-based detectors with the varying composition of the mobile phase during gradient elution in HPLC. A Corona charged aerosol detector was used in the experiments. The detector is characterized by a nearly universal response at a given, constant mobile-phase composition for sufficiently nonvolatile analytes. A second pump was used to deliver an exactly inverse gradient compared to the analytical HPLC system, and both flows were mixed in a tee piece before introduction to the Corona detector. The approach proposed made it possible to extend the universal response from isocratic to gradient elution conditions in HPLC, vastly improving the usefulness of this detection technique. The constant response of the detector obtained in this way was first demonstrated in flow injection analysis. Very similar calibration curves were obtained for six sulfonamide drugs after mobile-phase compensation. The approach was also applied to gradient elution with excellent results. The data were characterized by good precision ranging from 4% RSD at 10 mg/L to 1.6% RSD at 780 mg/L. The average limit of detection with a 2-microL injection was 0.5 mg/L, corresponding to 1 ng injected on the column. The approach proposed allows quantification of unknown compounds, e.g., in pharmaceutical mixtures. Measurement of analytes at a relative concentration of 0.05% versus the main component is demonstrated.Keywords
This publication has 7 references indexed in Scilit:
- Toward Single-Calibrant Quantification in HPLC. A Comparison of Three Detection Strategies: Evaporative Light Scattering, Chemiluminescent Nitrogen, and Proton NMRAnalytical Chemistry, 2005
- Improving Quantitative Measurements for the Evaporative Light Scattering DetectorChromatographia, 2004
- Evaporative light‐scattering detection coupled to microcolumn liquid chromatography for the analysis of underivatized amino acids: Sensitivity, linearity of response and comparisons with UV absorbance detectionJournal of Microcolumn Separations, 2001
- Nitrogen-specific liquid chromatography detector based on chemiluminescence: Application to the analysis of ammonium nitrogen in waste waterJournal of Chromatography A, 1992
- Comparison of refractive index, low-wavelength UV and UV visualisation detection methods for the high-performance liquid chromatographic determination of hexamethonium bromide in an injection formulationJournal of Chromatography A, 1986
- Separation of aromatic hydrocarbons using bonded-phase charge-transfer liquid chromatographyAnalytical Chemistry, 1984
- Evaporative analyzer as a mass detector for liquid chromatographyAnalytical Chemistry, 1978