Gehalt an spezifischen Antik rpern in handels blichen intraven s applizierbaren Gammaglobulinpr paraten

Abstract
No significant differences in the composition or concentration of specific antibodies against microbial antigens could be measured in five commercially available human immunoglobulin preparations for intravenous use. Prediction of prophylactic or therapeutic efficiency of such preparations according to their antibody content seems to be only partially possible. Human immunoglobulins for intravenous use should be free from irregular antibodies against erythrocyte antigens of the Rh-systems, as found in one of the specimens tested. Nennenswerte Unterschiede hinsichtlich des quantitativen und qualitativen Gehalts an spezifischen Antikörpern gegen mikrobielle Antigene waren in fünf handelsüblichen intravenös applizierbaren Gammaglobulinpräparaten nicht nachweisbar. Eine Aussage über die prophylaktische und therapeutische Effizienz auf Grund des Antikörpergehalts erscheint nur bedingt möglich. Irreguläre Antikörper gegen Antigene des Rh-Systems, wie sie sich in meßbarer Konzentration in den Präparaten eines Herstellers fanden, sollten in Gammaglobulinpräparaten nicht enthalten sein.