Interfacing the Orbitrap Mass Analyzer to an Electrospray Ion Source
Top Cited Papers
- 28 February 2003
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (7) , 1699-1705
- https://doi.org/10.1021/ac0258047
Abstract
The orbitrap mass analyzer employs the trapping of pulsed ion beams in an electrostatic quadro-logarithmic field. This field is created between an axial central electrode and a coaxial outer electrode. Stable ion trajectories combine rotation around the central electrode with harmonic oscillations along it. The frequencies of axial oscillations and hence mass-to-charge ratios of ions are obtained using fast Fourier transform of the image current detected on the two split halves of the outer electrode. This work proves that such a trap could be coupled to a continuous, electrospray, ion source. Such a coupling necessitated the development of an rf-only quadrupole for external accumulation of ions and their injection in very short (<1 μs) ion bunches. Along with good sensitivity, this mass spectrometer provides mass resolving power up to 150 000 fwhm, mass accuracies within a few parts per million, and relative mass range up to 8-fold. The maximum number of ions available for analysis is limited by the space-charge capacity of the accumulation quadrupole.Keywords
This publication has 7 references indexed in Scilit:
- Ion discrimination during ion accumulation in a quadrupole interface external to a Fourier transform ion cyclotron resonance mass spectrometerInternational Journal of Mass Spectrometry, 2001
- High Sensitivity Fourier Transform Ion Cyclotron Resonance Mass Spectrometry for Biological Analysis with Nano-LC and Microelectrospray IonizationAnalytical Chemistry, 2001
- Duty Cycle Improvement for a Quadrupole—Time-of-Flight Mass Spectrometer and its Use for Precursor Ion ScansEuropean Journal of Mass Spectrometry, 2000
- Electrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass AnalysisAnalytical Chemistry, 2000
- Proteome analysis using selective incorporation of isotopically labeled amino acidsJournal of the American Society for Mass Spectrometry, 2000
- External accumulation of ions for enhanced electrospray ionization fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 1997
- Experimental determination of the number of trapped ions, detection limit, and dynamic range in Fourier transform ion cyclotron resonance mass spectrometryAnalytical Chemistry, 1993