Voxel size effects in three‐dimensional nuclear magnetic resonance microscopy performed for trabecular bone dosimetry
- 9 November 2000
- journal article
- Published by Wiley in Medical Physics
- Vol. 27 (11) , 2624-2635
- https://doi.org/10.1118/1.1315313
Abstract
An important problem in internal dosimetry is the assessment of energy deposition by beta particles within trabecular regions of the skeleton. Recent dosimetry methods for trabecular bone are based on Monte Carlo particle transport simulations within three‐dimensional (3D) images of real human bone samples. Nuclear magnetic resonance (NMR) microscopy is a 3D imaging technique of choice due to the large signal differential between bone tissue and the water‐filled marrow cavities. Image voxel sizes currently used in NMR microscopy are between and but the images are time consuming to acquire and can only be performed at present for in vitro samples. It is therefore important to evaluate what resolution is best suitable in order to properly characterize the trabecular microstructure, to adequately predict the tissue dosimetry, and to minimize imaging time. In this work, a mathematical model of trabecular bone, composed of a distribution of spherical marrow cavities, was constructed. The mathematical model was subsequently voxelized with different voxel sizes to to simulate 3D NMR images. For each image, voxels are assigned to either bone or marrow according to their enclosed marrow fraction. Next, the images are coupled to the EGS4 electron transport code and absorbed fractions to bone and marrow are calculated for a marrow source of monoenergetic electrons. Radionuclide S values are also determined for the voxelized images with results compared to data calculated for the pure mathematical sample. The comparison shows that for higher energy electrons good convergence of the results is seen even within images of poor resolution. Above 400 keV, a voxel resolution as large as results in dosimetry errors below For low‐energy electrons and high‐resolution images, the self‐dose to marrow is also determined to within 5% accuracy. Nevertheless, increased voxelization of the image overestimates the surface area of the bone‐marrow interface leading to errors in the cross‐dose to bone as high as 25% for some low‐energy beta emitters.Keywords
This publication has 20 references indexed in Scilit:
- A Comparative Study of Trabecular Bone Properties in the Spine and Femur Using High Resolution MRI and CTJournal of Bone and Mineral Research, 1998
- Probability‐based structural parameters from three‐dimensional nuclear magnetic resonance images as predictors of trabecular bone strengthMedical Physics, 1997
- Three-dimensional nuclear magnetic resonance microimaging of trabecular boneJournal of Bone and Mineral Research, 1995
- Role of trabecular morphology in the etiology of age-related vertebral fracturesCalcified Tissue International, 1993
- The architecture of bone marrow cell populationsThe International Journal of Cell Cloning, 1990
- Estimates of Absorbed Energy in Trabecular Bone Due to Beta-particles Or ElectronsHealth Physics, 1982
- Calculated dose factors for the radiosensitive tissues in bone irradiated by surface-deposited radionuclidesPhysics in Medicine & Biology, 1978
- Measurements of trabecular bone structure in man (for radionuclide dosimetryPhysics in Medicine & Biology, 1976
- Variation in trabecular structure of vertebrae with ageCalcified Tissue International, 1967
- Changes in resorption spaces in femoral cortical bone with ageThe Journal of Pathology and Bacteriology, 1965