Comparison of a Multiplex Flow Cytometric Assay with Enzyme-Linked Immunosorbent Assay for Quantitation of Antibodies to Tetanus, Diphtheria, and Haemophilus influenzae Type b
- 1 July 2002
- journal article
- research article
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 9 (4) , 872-6
- https://doi.org/10.1128/cdli.9.4.872-876.2002
Abstract
We developed a multiplexed indirect immunofluorescence assay for antibodies to Haemophilus influenza type b (Hib) polysaccharide and the toxoids of Clostridium tetani (Tet) and Corynebacterium diphtheriae (Dip) based on the Luminex multiple-analyte profiling system. A pooled serum standard was calibrated against World Health Organization standards for Dip and Tet and an international standard for Hib. The multiplexed Luminex assay was compared to individual enzyme-linked immunosorbent assays (ELISAs) for the same analytes. By both methods, 75 (92.6%) of 81 of random serum samples had protective levels of antibody to Tet (> or = 0.1 IU/ml). For Dip, 81.5% of the samples had protective antibody levels (> or = 0.1 IU/ml) by ELISA and 80.2% had protective antibody levels by Luminex. Protective levels (> or = 1.0 microg/ml) of antibody to Hib were found in 45.0% of the samples tested by ELISA and in 39.0% of the samples tested by Luminex. The correlations (R(2)) between ELISA and Luminex of the 81 samples were 0.96, 0.96, and 0.91 for Tet, Dip, and Hib, respectively. There was also similar agreement between Luminex and ELISA for sera collected before and 1 month after Tet, Dip, and Hib vaccine administration. Both methods detected strong postvaccination responses. The Luminex method is an attractive alternative to ELISA since it reduces labor and reagent costs, as well as assay time.Keywords
This publication has 16 references indexed in Scilit:
- A Multiplexed Fluorescent Microsphere Immunoassay for Antibodies to Pneumococcal Capsular PolysaccharidesAmerican Journal of Clinical Pathology, 2002
- Combination VaccinesInfectious Disease Clinics of North America, 2001
- Pneumococcal Type 22F Polysaccharide Absorption Improves the Specificity of a Pneumococcal-Polysaccharide Enzyme-Linked Immunosorbent AssayClinical and Diagnostic Laboratory Immunology, 2001
- Recommended childhood immunization schedule--United States, 2001.2001
- Combination vaccines: Problems and promiseThe Journal of Pediatrics, 2000
- Diminution of the anti-polyribosylribitol phosphate response to a combined diphtheria-tetanus-acellular pertussis/Haemophilus influenzae type b vaccine by concurrent inactivated poliovirus vaccinationThe Pediatric Infectious Disease Journal, 2000
- An ELISA employing a Haemophilus influenzae type b oligosaccharide-human serum albumin conjugate correlates with the radioantigen binding assayJournal of Immunological Methods, 1990
- Enhancement by N-hydroxysulfosuccinimide of water-soluble carbodiimide-mediated coupling reactionsAnalytical Biochemistry, 1986
- The Protective Level of Serum Antibodies to the Capsular Polysaccharide of Haemophilus influenzae type bThe Journal of Infectious Diseases, 1984
- The Protective Level of Serum Antibodies to the Capsular Polysaccharide of Haemophilus influenzae Type bThe Journal of Infectious Diseases, 1983