Internal cardiac defibrillation in man: pronounced improvement with sequential pulse delivery to two different lead orientations.
- 1 March 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 73 (3) , 484-491
- https://doi.org/10.1161/01.cir.73.3.484
Abstract
Wider applicability of an implantable automatic defibrillator depends on achieving internal cardiac defibrillation consistently with the lowest possible energy. In animal studies, we have found that the cardiac defibrillation threshold could be reduced when sequential shocks separated in time and spacially arranged were delivered to the heart. We compared internal cardiac defibrillation using a single pulse shock delivered through an intravascular catheter with this new method for internal cardiac defibrillation in patients undergoing cardiac surgery for the correction of arrhythmias. For the single pulse shock and the first pulse of the sequential pulse shock, current was passed through an intravascular catheter with the catheter cathode at the apex of the right ventricle and the anode at the superior vena cava-atrial junction region. The second pulse of the sequential pulse countershock was delivered between the catheter cathode in the right ventricular apex and an oval plaque electrode secured on the laterobasal left ventricular epicardium as anode. With the single pulse alone for shock delivery, 12 patients could be defibrillated with an average of 20.1 +/- 16.8 J, with a corresponding leading-edge peak voltage and current of 836 +/- 319 V and 9.4 +/- 4.5 A, respectively. However, two of the patients could not be defibrillated with energies below 50 J. With the sequential pulse shock delivery, a significant reduction in all values were recorded. Mean total energy for defibrillation averaged 7.7 +/- 6.0 J. Leading-edge peak voltage and current from the catheter averaged 430 +/- 148 V and 5.0 +/- 2.8 A, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)This publication has 16 references indexed in Scilit:
- Improved internal defibrillation with twin pulse sequential energy delivery to different lead orientations in pigsThe American Journal of Cardiology, 1985
- Changes in pacing threshold and R wave amplitude after transvenous catheter countershockJournal of the American College of Cardiology, 1984
- Early Experience with an Implantable CardioverterNew England Journal of Medicine, 1984
- Pacing threshold changes after transvenous catheter countershockThe American Journal of Cardiology, 1984
- Role of a catheter lead system for transvenous countershock and pacing during electrophysiologic tests: An assessment of the usefulness of catheter shocks for terminating ventricular tachyarrhythmiasThe American Journal of Cardiology, 1983
- Treatment of malignant ventricular tachyarrhythmias with the automatic implantable defibrillatorInternational Journal of Cardiology, 1983
- Low energy counterchock using an intravascular catheter in an acute cardiac care settingThe American Journal of Cardiology, 1982
- Open chest defibrillation during cardiac surgery: Energy and current requirementsThe American Journal of Cardiology, 1980
- TRANSVENOUS AUTOMATIC DEFIBRILLATOR — PRELIMINARY CLINICAL TESTS OF ITS DEFIBRILLATING SUBSYSTEMAsaio Journal, 1972
- The physiologic basis for cardiac resuscitation from ventricular fibrillation—Method for serial defibrillationAmerican Heart Journal, 1940