Evaluation of the Respicon®as a personal inhalable sampler in industrial environments
- 28 August 2002
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Environmental Monitoring
- Vol. 4 (5) , 657-662
- https://doi.org/10.1039/b204985f
Abstract
The Respicon® has been introduced as a sampler for health related measurements of airborne contaminants at workplaces. The instrument is aimed at simultaneous collection of three health related aerosol fractions: (a) the coarser inhalable fraction, defining the aerosol fraction that may enter the nose and mouth during breathing; (b) the intermediate thoracic fraction, defining the fraction that may penetrate beyond the larynx and so reach the lung; and (c) the finer respirable fraction, defining the fraction that may penetrate to gas exchange region of the lung. The instrument has a number of features attractive to occupational hygienists: in addition to providing the three aerosol fractions simultaneously, it is light and compact enough to be used as a personal sampler, yet can be a tripod mounted for area sampling; it can provide samples not only for gravimetric analysis but also microscopic and chemical analyses; and it is also available in a photometric direct-reading version. The instrument has previously been evaluated as an area sampler and, in this mode of operation, has shown reasonable accuracy in collecting respirable, thoracic and inhalable particles, the latter up to particle diameters of ca. 80 µm. Except for some scattered unpublished data there exist no systematic investigations in the Respicon's performance when used as a personal sampler in the industrial environment. In this paper, we will report on a study of side by side comparison of the Respicon with the IOM inhalable sampler, regarded as a reference instrument for the inhalable fraction. The main study was performed at six different workplaces in a nickel refinery. Statistical analysis of the gravimetrically-determined concentration data reveals consistently lower aerosol exposure values for the Respicon as compared to the IOM sampler. The data for the nickel workplaces are compared with findings from other studies. The results are interpreted in the light of the overall results and the possibility of introducing a correction factor is discussed.Keywords
This publication has 10 references indexed in Scilit:
- Evaluation of personal aerosol samplers challenged with large particlesJournal of Aerosol Science, 2001
- Development of a novel calibration tool for workplace aerosol samplers - review of progress of EU projectJournal of Aerosol Science, 2000
- Evaluation of Six Inhalable Aerosol SamplersAihaj Journal, 2000
- Design and Performance of a New Personal Aerosol MonitorAerosol Science and Technology, 1999
- Characterisation of workers' exposure in a Russian nickel refineryPublished by Royal Society of Chemistry (RSC) ,1999
- Inhalable Aerosol SamplersApplied Occupational and Environmental Hygiene, 1998
- A COLLABORATIVE EUROPEAN STUDY OF PERSONAL INHALABLE AEROSOL SAMPLER PERFORMANCEAnnals of Occupational Hygiene, 1997
- Occupational exposure to inhalable and total aerosol in the primary nickel production industry.Occupational and Environmental Medicine, 1995
- ENTRY CHARACTERISTICS OF PRACTICAL WORKPLACE AEROSOL SAMPLERS IN RELATION TO THE ISO RECOMMENDATIONSAnnals of Occupational Hygiene, 1990
- A NEW PERSONAL SAMPLER FOR AIRBORNE TOTAL DUST IN WORKPLACESAnnals of Occupational Hygiene, 1986