Characteristics of the ‘Cryogenic-Wall’ Thermal Diffusion Column for Separation of Hydrogen Isotopes
- 1 May 1992
- journal article
- research article
- Published by Taylor & Francis in Fusion Technology
- Vol. 21 (3P2B) , 1959-1963
- https://doi.org/10.13182/fst92-a30007
Abstract
Experimental study for separation of hydrogen isotopes has been performed by using a ‘cryogenic-wall’ thermal diffusion column. The separation experiments were carried out with H-D system under total reflux and continuous feed operation mode. The dependence of the separation factor on the column pressure were examined for both experiments. In the total reflux experiments, the maximum separation factor of the ‘cryogenic-wall’ column was about 12.4 times larger than for the ‘water cooled-wall’. The effect of the feed flow rate on the separation factor and on the optimum pressure was examined in the continuous feed experiments. As the feed flow rate increased, the separation factor decrease appreciably, and the optimum pressure shift progressively to higher region.Keywords
This publication has 6 references indexed in Scilit:
- Separation of Hydrogen Isotopes by an Advanced Thermal Diffusion Column Using Cryogenic-WallFusion Technology, 1991
- Preliminary Experiments of Separation of Hydrogen Isotopes by “Cryogenic-Wall” Thermal Diffusion ColumnJournal of Nuclear Science and Technology, 1990
- Possibility of Remarkable Enhancement of Separation Factor by “Cryogenic-Wall” Thermal Diffusion ColumnJournal of Nuclear Science and Technology, 1990
- Optimum Pressure for Total-Reflux Operated Thermal Diffusion Column for Isotope SeparationJournal of Nuclear Science and Technology, 1990
- Experimental Apparatus for Thermal Diffusion Process in the Tritium Process LaboratoryFusion Technology, 1988
- Pressure Dependence of Separative Characteristics of Thermal Diffusion Column for H2-HT Isotope SeparationFusion Technology, 1988