The purpose of this work was to compare intracranial magnetic resonance angiography (MRA) image quality using three different radiofrequency coils. The three coil types included a reduced volume quadrature birdcage coil with endcap, a commercially available quadrature birdcage head coil, and a four‐element phased‐array coil. Signal‐to‐noise ratio (SNR) measurements were obtained from comparison studies performed on a uniform cylindrical phantom. MRA comparisons were performed using data acquired from 15 volunteers and applying a thick‐slab three‐dimensional time‐of‐flight sequence. Analysis was performed using the signal difference‐to‐noise ratio, a quantitative measure of the relative vascular signal. The reduced‐volume endcap and phased‐array coils, which were designed specifically for imaging the intracranial volume of the head, improved the image SNR and vascular detail considerably over that obtained using the commercially available head coil. The endcap coil configuration provided the best vascular signal overall, while the phased‐array coil provided the best results for arteries close to the coil elements. J. Magn. Reson. Imaging 2000;11:458–468.Keywords
This publication has 24 references indexed in Scilit:
- Theory of the quadrature elliptic birdcage coilMagnetic Resonance in Medicine, 1997
- Integrated RF coil with stabilization for fMRI human cortexMagnetic Resonance in Medicine, 1997
- A method to create an optimum current distribution and homogeneous B1 field for elliptical birdcage coilsMagnetic Resonance in Medicine, 1997
- Surface coil phased arrays for high‐resolution imaging of the carotid arteriesJournal of Magnetic Resonance Imaging, 1996
- Lower extremities: MR angiography with a unilateral telescopic phased-array coil.Radiology, 1995
- Phased Array Coils for Upper Extremity MRAMagnetic Resonance in Medicine, 1995
- Three-dimensional time-of-flight MR angiography with a surface coil: evaluation in 12 subjects.American Journal of Roentgenology, 1992
- Volume imaging with MR phased arraysMagnetic Resonance in Medicine, 1991
- The NMR phased arrayMagnetic Resonance in Medicine, 1990
- Noise correlations in data simultaneously acquired from multiple surface coil arraysMagnetic Resonance in Medicine, 1990