Isotope ratio monitoring of small molecules and macromolecules by liquid chromatography coupled to isotope ratio mass spectrometry
- 26 August 2005
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 19 (18) , 2689-2698
- https://doi.org/10.1002/rcm.2117
Abstract
In the field of isotope ratio mass spectrometry, the introduction of an interface allowing the connection of liquid chromatography (LC) and isotope ratio mass spectrometry (IRMS) has opened a range of new perspectives. The LC interface is based on a chemical oxidation, producing CO2 from organic molecules. While first results were obtained from the analysis of low molecular weight compounds, the application of compound-specific isotope analysis by irm-LC/MS to other molecules, in particular biomolecules, is presented here. The influence of the LC flow rate on the CO2 signal and on the observed δ13C values is demonstrated. The limits of quantification for angiotensin III and for leucine were 100 and 38 pmol, respectively, with a standard deviation of the δ13C values better than 0.4‰. Also, accuracy and precision of δ13C values for elemental analyser-IRMS and flow injection analysis-IRMS (FIA-LC/MS) were compared. For compounds with molecular weights ranging from 131 to 66 390 Da, precision was better than 0.3‰, and accuracy varied from 0.1 to 0.7‰. In a second part of the work, a two-dimensional (2D)-LC method for the separation of 15 underivatised amino acids is demonstrated; the precision of δ13C values for several amino acids by irm-LC/MS was better than 0.3‰ at natural abundance. For labelled mixtures, the coefficient of variation was between 1% at 0.07 atom % excess (APE) for threonine and alanine, and around 10% at 0.03 APE for valine and phenylalanine. The application of irm-LC/MS to the determination of the isotopic enrichment of 13C-threonine in an extract of rat colon mucosa demonstrated a precision of 0.5‰, or 0.001 atom %. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 40 references indexed in Scilit:
- Practical considerations in the gas chromatography/combustion/isotope ratio monitoring mass spectrometry of 13C‐enriched compounds: detection limits and carryover effectsRapid Communications in Mass Spectrometry, 2003
- Application of high‐precision isotope ratio monitoring mass spectrometry to identify the biosynthetic origins of proteinsProtein Science, 2001
- Isotope-Ratio-Monitoring Liquid Chromatography Mass Spectrometry (IRM-LCMS): First Results from a Moving Wire Interface SystemIsotopes in Environmental and Health Studies, 1996
- Continuous-Flow Isotope Ratio Mass Spectrometry Using the Chemical Reaction Interface with Either Gas or Liquid Chromatographic IntroductionAnalytical Chemistry, 1996
- Isotopic Differences in Human Growth Hormone PreparationsAnalytical Chemistry, 1996
- Application of high-performance liquid chromatography/chemical reaction interface mass spectrometry for the analysis of conjugated metabolites: A demonstration using deuterated acetaminophenJournal of Mass Spectrometry, 1994
- High-precision liquid chromatography-combustion isotope ratio mass spectrometryAnalytical Chemistry, 1993
- Measurement of muscle protein fractional synthetic rate by capillary gas chromatography/combustion isotope ratio mass spectrometryJournal of Mass Spectrometry, 1992
- Mass spectrometric analysis of sulfur in microgram quantities of biological macromolecules using a reaction interfaceJournal of Mass Spectrometry, 1986
- A new technique for the detection of metabolites labelled by the isotope13C using mass fragmentographyJournal of Mass Spectrometry, 1976