Setting Mean Airway Pressure during High-frequency Oscillatory Ventilation According to the Static Pressure–Volume Curve in Surfactant-deficient Lung Injury
Open Access
- 1 December 2003
- journal article
- pain medicine
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 99 (6) , 1313-1322
- https://doi.org/10.1097/00000542-200312000-00012
Abstract
Background: Numerous studies suggest setting positive end-expiratory pressure during conventional ventilation according to the static pressure-volume (P-V) curve, whereas data on how to adjust mean airway pressure (P(aw)) during high-frequency oscillatory ventilation (HFOV) are still scarce. The aims of the current study were to (1) examine the respiratory and hemodynamic effects of setting P(aw) during HFOV according to the static P-V curve, (2) assess the effect of increasing and decreasing P(aw) on slice volumes and aeration patterns at the lung apex and base using computed tomography, and (3) study the suitability of the P-V curve to set P(aw) by comparing computed tomography findings during HFOV with those obtained during recording of the static P-V curve at comparable pressures. Methods: Saline lung lavage was performed in seven adult pigs. P-V curves were obtained with computed tomography scanning at each volume step at the lung apex and base. The lower inflection point (Pflex) was determined, and HFOV was started with P(aw) set at Pflex. The pigs were provided five 1-h cycles of HFOV. P(aw), first set at Pflex, was increased to 1.5 times Pflex (termed 1.5 Pflex(inc)) and 2 Pflex and decreased thereafter to 1.5 times Pflex and Pflex (termed 1.5 Pflex(dec) and Pflex(dec)). Hourly measurements of respiratory and hemodynamic variables as well as computed tomography scans at the apex and base were made. Results: High-frequency oscillatory ventilation at a P(aw) of 1.5 Pflex(inc) reestablished preinjury arterial oxygen tension values. Further increase in P(aw) did not change oxygenation, but it decreased oxygen delivery as a result of decreased cardiac output. No differences in respiratory or hemodynamic variables were observed when comparing HFOV at corresponding P(aw) during increasing and decreasing P(aw). Variation in total slice lung volume (TLVs) was far less than expected from the static P-V curve. Overdistended lung volume was constant and less than 3% of TLVs. TLVs values during HFOV at Pflex, 1.5 Pflex(inc), and 2 Pflex were significantly greater than TLVs values at corresponding tracheal pressures on the inflation limb of the static P-V curve and located near the deflation limb. In contrast, TLVs values during HFOV at decreasing P(aw) (i.e., 1.5 Pflex(dec) and Pflex(dec)) were not significantly greater than corresponding TLV on the deflation limb of the static P-V curves. The marked hysteresis observed during static P-V curve recordings was absent during HFOV. Conclusions: High-frequency oscillatory ventilation using P(aw) set according to a static P-V curve results in effective lung recruitment, and slice lung volumes during HFOV are equal to those from the deflation limb of the static P-V curve at equivalent pressures.Keywords
This publication has 31 references indexed in Scilit:
- Recruitment aneuvers to achieve an “open lung”— Whether and how?Critical Care Medicine, 2001
- High-Frequency Ventilation for Acute Lung Injury and ARDSChest, 2000
- The Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2000
- Effect of Mechanical Ventilation on Inflammatory Mediators in Patients With Acute Respiratory Distress SyndromeJAMA, 1999
- Effect of I/E ratio on mean alveolar pressure during high-frequency oscillatory ventilationJournal of Applied Physiology, 1999
- Mechanical Ventilation Affects Local and Systemic Cytokines in an Animal Model of Acute Respiratory Distress SyndromeAmerican Journal of Respiratory and Critical Care Medicine, 1999
- Protective Ventilation for Patients with Acute Respiratory Distress SyndromeNew England Journal of Medicine, 1998
- High-frequency oscillatory ventilation for adult respiratory distress syndromeCritical Care Medicine, 1997
- Volume recruitment maneuvers are less deleterious than persistent low lung volumes in the atelectasisprone rabbit lung during high-frequency oscillationCritical Care Medicine, 1993
- Proximal, Tracheal, and Alveolar Pressures during High-Frequency Oscillatory Ventilation in a Normal Rabbit ModelPediatric Research, 1990