Left and Right Pump Output Control in One‐Piece Electromechanical Total Artificial Heart
- 1 March 1993
- journal article
- Published by Wiley in Artificial Organs
- Vol. 17 (3) , 176-184
- https://doi.org/10.1111/j.1525-1594.1993.tb00427.x
Abstract
Left master alternate (LMA) ejection control based on the left pump fill method was implemented for a one-piece electromechanical total artificial heart (TAH). The TAH consists of left and right pusher-plate-type blood pumps sandwiching a compact electromechanical actuator comprising a direct current (DC) brushless motor and a planetary roller screw. The motor rotation is controlled on the basis of the roller-screw position as detected by a Hall effect sensor and a commutation pulse counting method. Since the pusher-plate shaft and roller screw are decoupled during filling, both pumps fill passively with the right and left atrial pressure. To obtain response to the right atrial pressure change in the LMA mode, the left fill trigger level as detected by a Hall effect position sensor is adjusted to operate the pump at a higher rate and to drive the right pump at 85-90% of the full stroke level. The in vitro evaluation demonstrated that this method can respond to right atrial pressure changes provided that the right pump is operated at less than the full stroke level. When the preload is high and the right pump goes into full stroke operation, the left eject level can be decreased to run the pump at a higher rate and to transfer more blood from the right to the left. In the in vivo evaluation, which lasted 1 week in a 95 kg calf, the left and right atrial pressures were kept within physiological ranges.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 10 references indexed in Scilit:
- Development of a Totally Implantable Electromechanical Total Artificial Heart: Baylor TAHArtificial Organs, 2008
- Right-Left Ventricular output Balance in the Totally Implantable Artificial HeartThe International Journal of Artificial Organs, 1991
- Characterization of Rehydrated Gelatin GelsArtificial Organs, 1991
- Toward a totally implantable artificial heart: Development status at Cleveland ClinicPublished by Springer Nature ,1991
- Permanent circulatory support systems at the Pennsylvania State UniversityIEEE Transactions on Biomedical Engineering, 1990
- A Unique Left-Right Flow Imbalance Compensation Scheme for an Implantable Total Artificial HeartAnnual Northeast Bioengineering Conference, 1989
- Pusher‐Plate Type TAH System Operated in the Left and Right Free‐Running Variable Rate ModeArtificial Organs, 1981
- TRANSIENT AND PERMANENT PROBLEMS ASSOCIATED WITH THE TOTAL ARTIFICIAL HEART IMPLANTATIONAsaio Journal, 1979
- HIGH FLEX RUBBER FOR BLOOD PUMP DIAPHRAGMSAsaio Journal, 1977