Use of single-collector and multi-collector ICP-mass spectrometry for isotopic analysis
Top Cited Papers
- 24 April 2009
- journal article
- review article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 24 (7) , 863-886
- https://doi.org/10.1039/b903887f
Abstract
This article is intended as a tutorial review on the use of single-collector and multi-collector ICPMS for isotope ratio determination. The monitoring and quantification of both induced and natural differences in the isotopic composition of target elements is covered. The capabilities of various types of ICPMS instruments for isotope ratio measurements are addressed and issues, such as the occurrence of mass discrimination and detector dead time effects and appropriate ways of correcting for the biases they give rise to are discussed. Applications relying on induced changes include elemental assay via isotope dilution, tracer experiments with stable isotopes, aiming at a more profound insight into physical processes or (bio)chemical reactions, and nuclear applications. Attention is also paid to the origin of natural variations in the isotopic composition, with focus onto the mechanisms behind the isotopic variation for those elements for which isotopic analysis can be realized using ICP-mass spectrometry, i.e. the occurrence of radiogenic nuclides formed as a result of the decay of naturally occurring and long-lived radionuclides and mass fractionation as a result of thermodynamic and kinetic isotope fractionation effects. Geochronological dating via the Rb–Sr, U, Th–Pb, and Pb–Pb methods is briefly explained and also the use of Sr and Pb isotopic analysis for provenance determination studies is covered. Subsequently, applications based on isotopic analysis of elements showing a much narrower range of variation as a result of isotope fractionation are described. Next to provenance studies, such applications include the use of isotope ratios in geochemical, environmental and biomedical studies. Although it is not the intention to comprehensively review the literature, several examples of published applications are used to illustrate the capabilities of both single-collector and multi-collector ICPMS in this context. Thereby, attention is devoted both to widely accepted applications and to more ‘exotic’ applications, aiming at an extension of the application range.Keywords
This publication has 162 references indexed in Scilit:
- Sulfur isotope measurement of sulfate and sulfide by high-resolution MC-ICP-MSChemical Geology, 2008
- In situ determination of precise stable Si isotope ratios by UV-femtosecond laser ablation high-resolution multi-collector ICP-MSChemical Geology, 2008
- Evidence for mass-independent and mass-dependent fractionation of the stable isotopes of mercury by natural processes in aquatic ecosystemsApplied Geochemistry, 2008
- Authentication of Kalix (N.E. Sweden) vendace caviar using inductively coupled plasma-based analytical techniques: Evaluation of different approachesAnalytica Chimica Acta, 2007
- A review of isotopic composition as an indicator of the natural and anthropogenic behavior of mercuryApplied Geochemistry, 2006
- A review of mass-dependent fractionation of selenium isotopes and implications for other heavy stable isotopesChemical Geology, 2004
- Rb isotope dilution analyses by MC-ICPMS using Zr to correct for mass fractionation: towards improved Rb–Sr geochronology?Chemical Geology, 2002
- High accuracy analysis of low level sulfur in diesel fuel by isotope dilution high resolution ICP-MS, using silicon for mass bias correction of natural isotope ratiosJournal of Analytical Atomic Spectrometry, 2001
- Mass spectrometry and geochronologyMass Spectrometry Reviews, 1998
- High precision 230Th/232Th and 234U/238U measurements using energyfiltered ICP magnetic sector multiple collector mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1997