Reproducibility of Ultrasonographically Determined Intima-Media Thickness Is Dependent on Arterial Wall Thickness
- 1 October 1997
- journal article
- Published by Wolters Kluwer Health in Stroke
- Vol. 28 (10) , 1972-1980
- https://doi.org/10.1161/01.str.28.10.1972
Abstract
Background and Purpose We compared the reproducibility of B-mode ultrasonographic measurements of intima-media thickness (IMT) in various segments of the right carotid artery and examined whether measurement error was associated with IMT or cardiovascular risk factor levels. Methods In 1994/1995 a total of 6676 participants in the Tromsø Study underwent ultrasound examination of common carotid artery IMT. Reproducibility of measurements was assessed by inviting 111 participants to a second ultrasound scan within 3 weeks of the first scan. On each occasion the subjects were examined by three sonographers. Results The mean between-observer absolute differences in IMT in the far wall of the bifurcation and the near and far walls of the common carotid artery were 0.15, 0.10, and 0.08 mm, respectively. The corresponding within-observer differences were 0.15, 0.10, and 0.06 mm, respectively. Approximately 70% to 80% of total measurement variability was due to differences among sonographers; the rest was attributable to within-reader variability. Measurement error increased significantly with increasing IMT: the increase was more than twofold over the range of measurements. Cardiovascular risk factor levels were not associated with measurement variability when we controlled for IMT. Conclusions We conclude that B-mode ultrasound provides reproducible estimates of the IMT in both the near and far walls of the carotid artery. Although measurement error is generally small, it increases proportionally with the level of IMT.Keywords
This publication has 12 references indexed in Scilit:
- Lessons learned from clinical trials with ultrasound end‐pointsJournal of Internal Medicine, 1994
- Reproducibility of carotid vessel wall thickness measurements. the rotterdam studyJournal of Clinical Epidemiology, 1994
- B-mode ultrasound images of the carotid artery wall: correlation of ultrasound with histological measurementsAtherosclerosis, 1993
- Measurement of intima-media thickness of common carotid arteries with high-resolution B-mode ultrasonography: Inter- and intra-observer variabilityUltrasound in Medicine & Biology, 1991
- High‐Resolution B‐Mode Ultrasound Reading Methods in the Atherosclerosis Risk in Communities (ARIC) CohortJournal of Neuroimaging, 1991
- Ultrasound measurement of wall thickness in the carotid artery: fundamental principles and description of a computerized analysing systemClinical Physiology and Functional Imaging, 1991
- Determinants of carotid intima‐media thickness: a population‐based ultrasonography study in Eastern Finnish menJournal of Internal Medicine, 1991
- How independent are “independent” effects? relative risk estimation when correlated exposures are measured impreciselyJournal of Clinical Epidemiology, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- The Tromsø Heart StudyActa Medica Scandinavica, 1976