Chromium(III) Porphyrin as a Selective Ionophore in a Salicylate-Selective Membrane Electrode
- 6 June 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (14) , 3312-3320
- https://doi.org/10.1021/ac020099n
Abstract
The construction, potentiometric response properties, and applications of a novel ion-selective electrode with high selectivity toward salicylate are described. Chromium(III) tetraphenylporphyrin chloride was used as ion carrier into plasticized PVC membrane. This ionophore is capable of serving as both a positively charged and neutral carrier, depending on the pH of the sample solution. The influence of several variables was investigated to optimize the potentiometric response and selectivity of the electrode. The resulting electrode demonstrates a near-Nernstian response over a wide range of salicylate concentration (10-6−10-1 M). This electrode has a fast response time and micromolar detection limit and could be used over a wide pH range (3−9). The proposed electrode showed very high selectivity for salicylate over a number of common inorganic and organic anions. The specific interaction of salicylate with the central metal of porphyrin is described based on UV−visible absorption spectra. The electrode was successfully applied to the determination of salicylate in pharmaceutical preparations and clinical samples.Keywords
This publication has 27 references indexed in Scilit:
- Salicylate-Selective Electrodes Based on Al(III) and Sn(IV) SalophensAnalytical Chemistry, 2000
- Thiocyanate-selective electrodes based on nickel and iron phthalocyaninesAnalytica Chimica Acta, 1999
- PVC-Based Mn(III) Porphyrin Membrane-Coated Graphite Electrode for Determination of HistidineAnalytical Chemistry, 1999
- Anion selective polymeric membrane electrodes based on metallocenesAnalytica Chimica Acta, 1995
- Role of axial ligation on potentiometric response of Co(III) tetraphenylporphyrin-doped polymeric membranes to nitrite ionsAnalytica Chimica Acta, 1995
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988
- Membrane-dialyzer injection loop for enhancing the selectivity of anion-responsive liquid-membrane electrodes in flow systems Part 2. A selective sensing system for salicylateAnalytica Chimica Acta, 1986
- Ion-selective electrodes based on siderophores: Salicylate response of a ferrimycobactin membraneAnalytica Chimica Acta, 1986
- Enzyme electrode for the determination of salicylateAnalytica Chimica Acta, 1984
- On the preparation of metalloporphyrinsJournal of Inorganic and Nuclear Chemistry, 1970